Installation – B&B Electronics 7018TX - Manual User Manual
Page 7

(Revised 8/3/2009)
Page 7 of 138
Hazardous Location Installation Requirements
1.
This equipment is suitable for use in Class I, Div. 2, Groups A, B, C, D or non-hazardous locations 
only. 
 
2. 
WARNING: Explosion Hazard – Substitution of components may impair suitability for Class I, 
Div. 2. 
3.
WARNING: Explosion Hazard - do not disconnect while circuit is live, unless area is known to be 
non-hazardous. 
4.
WARNING: Explosion Hazard – do not replace the device unless power has been switched off or 
the area is known to be non-hazardous. 
5.
Use 90°C or higher rated Copper wire, (0.22Nm) 2lb/in Tightening torque for field installed 
conductors. 
Please make sure the 7018 Series Ethernet Switch package contains the following items: 
 
1. 7018 Series Switch 
2. Product CD 
 
Contact your carrier if any items are damaged. 
 
Installation 
 
Read the following warning before beginning the installation: 
 
WARNING 
 
Never install or work on electrical equipment or cabling during periods of lightning activity. Never connect 
or disconnect power when hazardous gasses are present. 
 
Disconnect the power cable before removing any enclosure panel. 
 
UNPACKING 
 
Remove all the equipment from the packaging, and store the packaging in a safe place. File any damage 
claims with the carrier. 
 
CLEANING 
Clean only with a damp cloth.