1.32. Set real time clock
You may update the router
‟s internal clock at any time using a NTP server by
selecting the Set Real Time Clock menu item. Enter the IP address or domain name of the
NTP Server and click Apply to set the clock.
Fig. 67: Set real time clock
1.33. Set SMS service center address
The SPECTRE RT industrial router does not support the Set SMS service center
address option.
The SMS service center phone number is normally programmed into the SIM card by the
carrier and does not need to be manually entered. However, in some cases, it may be
necessary to set the phone number of the SMS service center in order to send SMS
messages. This parameter cannot be set if the SIM card already contains the SMSC
information. The phone number can be entered with or without an international prefix. For
example: +420 xxx xxx xxx. If you are unable to send or receive SMS messages, contact
your carrier to find out if this parameter is required. This parameter is provisioned
automatically by the carrier on CDMA networks and does not need to be manually entered.
Fig. 68: Set SMS service center address
1.34. Unlock SIM card
The SPECTRE RT industrial router does not support the Unlock SIM card option.
You may lock the SIM card with a 4-8 digit PIN (Personal Identification Number) code
to prevent unauthorized use of the SIM card. The PIN code must be entered each time that
the SIM card is powered up. The SPECTRE 3G router supports the use of SIM card with a
PIN number. Enter the PIN number into the SIM PIN field on the configuration page and
select Apply.
Access to the SIM card is blocked if the PIN code is incorrectly entered 3 times.
Contact technical support if the SIM card has been blocked.
Fig. 69: Unlock SIM card