beautypg.com

Rainbow Electronics MG260 User Manual

Page 34

background image

MG260 Product Specification

This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged without prior written
agreement.



POWER SUPPLY


ONKEY

T

on/off-hold

(1 s min)



INTERNAL RST




STATE OF THE MODULE



Module OFF

I

BB+RF

< 10 µA

T

rst

(240 ms typ)

RESET mode

I

BB+RF

=20 to 40 mA



Module ON

I

BB+RF

<120 mA

(no loc. update)


AT answers « OK »

Module READY

SIM and Network dependent

I

BB+RF

= overall current consumption (Base Band + RF part)



Figure 9: Power-ON sequence diagram (no PIN code activated)

2.5.2.2.2 Power OFF

To properly power OFF the module, the application must set the ONKEY signal to low and
then send the AT+CPOF command to de-register from the network and switch off the
module. Once the « OK » response is issued by the module, the power supply can be
switched off.

POWER SUPPLY

ONKEY

AT COMMAND

AT+CPOF

OK response



STATE OF THE MODULE

Module

READY

Network dependent

Module OFF

I

BB+RF

<100 µA

I

BB+RF

= overall current consumption (Base Band + RF part)

Figure 10: Power-OFF sequence diagram