Rainbow Electronics MG260 User Manual
Page 34
MG260 Product Specification
This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged without prior written
agreement.
POWER SUPPLY
ONKEY
T
on/off-hold
(1 s min)
INTERNAL RST
STATE OF THE MODULE
Module OFF
I
BB+RF
< 10 µA
T
rst
(240 ms typ)
RESET mode
I
BB+RF
=20 to 40 mA
Module ON
I
BB+RF
<120 mA
(no loc. update)
AT answers « OK »
Module READY
SIM and Network dependent
I
BB+RF
= overall current consumption (Base Band + RF part)
Figure 9: Power-ON sequence diagram (no PIN code activated)
2.5.2.2.2 Power OFF
To properly power OFF the module, the application must set the ONKEY signal to low and
then send the AT+CPOF command to de-register from the network and switch off the
module. Once the « OK » response is issued by the module, the power supply can be
switched off.
POWER SUPPLY
ONKEY
AT COMMAND
AT+CPOF
OK response
STATE OF THE MODULE
Module
READY
Network dependent
Module OFF
I
BB+RF
<100 µA
I
BB+RF
= overall current consumption (Base Band + RF part)
Figure 10: Power-OFF sequence diagram