Ac characteristics – Rainbow Electronics AT24C128 User Manual
Page 5

5
AT24C128/256
0670H–SEEPR–07/02
AC Characteristics
Notes:
1. This parameter is characterized and is not 100% tested.
2. AC measurement conditions:
R
L
(connects to V
CC
): 1.3 k
Ω (2.5V, 5V), 10 kΩ (1.8V)
Input pulse voltages: 0.3 V
CC
to 0.7 V
CC
Input rise and fall times:
≤50 ns
Input and output timing reference voltages: 0.5 V
CC
Applicable over recommended operating range from T
A
= -40
°C to +85°C, V
CC
= +1.8V to +5.5V, CL = 100 pF (unless oth-
erwise noted). Test conditions are listed in Note 2.
Symbol
Parameter
1.8-volt
2.5-volt
5.0-volt
Units
Min
Max
Min
Max
Min
Max
f
SCL
Clock Frequency, SCL
100
400
1000
kHz
t
LOW
Clock Pulse Width Low
4.7
1.3
0.4
µs
t
HIGH
Clock Pulse Width High
4.0
0.6
0.4
µs
t
AA
Clock Low to Data Out Valid
0.1
4.5
0.05
0.9
0.05
0.55
µs
t
BUF
Time the bus must be free before a new
transmission can start
(1)
4.7
1.3
0.5
µs
t
HD.STA
Start Hold Time
4.0
0.6
0.25
µs
t
SU.STA
Start Set-up Time
4.7
0.6
0.25
µs
t
HD.DAT
Data In Hold Time
0
0
0
µs
t
SU.DAT
Data In Set-up Time
200
100
100
ns
t
R
Inputs Rise Time
(1)
1.0
0.3
0.3
µs
t
F
Inputs Fall Time
(1)
300
300
100
ns
t
SU.STO
Stop Set-up Time
4.7
0.6
0.25
µs
t
DH
Data Out Hold Time
100
50
50
ns
t
WR
Write Cycle Time
20
10
10
ms
Endurance
(1)
5.0V, 25°C, Page Mode
100K
100K
100K
Write
Cycles