Dc and ac operating conditions for read operation – Rainbow Electronics AT27LV520 User Manual
Page 4

AT27LV520
4
Note:
1. V
CC
standby current will be slightly higher with ALE, Ai, and ADi at TTL levels.
DC and AC Operating Conditions for Read Operation
AT27LV520-70
AT27LV520-90
Operating Temp. (Case)
Com.
0°C - 70°C
0°C - 70°C
Ind.
-40°C - +85°C
-40°C - +85°C
V
CC
Supply
3.0V to 3.6V
3.0V to 3.6V
5V
±=10%
5V
±=10%
DC and Operating Characteristics for Read Operation
Symbol
Parameter
Condition
Min
Max
Units
V
CC
= 3.0V to 3.6V
I
LI
Input Load Current
V
IN
= 0V to V
CC
±1
µA
I
LO
Output Leakage Current
V
OUT
= 0V to V
CC
±5
µA
I
SB
(1)
V
CC
Standby Current
ALE = V
CC
± 0.3V; Ai, ADi = GND/V
CC
± 0.3V
20
µA
I
CC
V
CC
Active Current
f = 5 MHz, I
OUT
= 0 mA, ALE = V
IL
8
mA
V
IL
Input Low Voltage
-0.6
0.8
V
V
IH
Input High Voltage
2.0
V
CC
+ 0.5
V
V
OL
Output Low Voltage
I
OL
= 2.0 mA
0.4
V
V
OH
Output High Voltage
I
OH
= -2.0 mA
2.4
V
V
CC
= 4.5V to 5.5V
I
LI
Input Load Current
V
IN
= 0V to V
CC
±1
µA
I
LO
Output Leakage Current
V
OUT
= 0V to V
CC
±5
µA
I
SB
(1)
V
CC
Standby Current
ALE = V
CC
± 0.3V; Ai, ADi = GND/V
CC
± 0.3V
100
µA
I
CC
V
CC
Active Current
f = 5 MHz, I
OUT
= 0 mA, ALE = V
IL
20
mA
V
IL
Input Low Voltage
-0.6
0.8
V
V
IH
Input High Voltage
2.0
V
CC
+ 0.5
V
V
OL
Output Low Voltage
I
OL
= 2.1 mA
0.4
V
V
OH
Output High Voltage
I
OH
= -400 µA
2.4