Software data protection enable algorithm(1), Software data protection disable algorithm(1), Software protected write cycle waveforms(1)(2) – Rainbow Electronics AT28HC256 User Manual
Page 8: Software data protection enable algorith m, Software data protection disable algorit hm, Software protected write cycle wavefor ms
AT28HC256
8
Software Data Protection
Enable Algorithm
Notes for software program code:
1.
Data Format: I/O7 - I/O0 (Hex);
Address Format: A14 - A0 (Hex).
2.
Write Protect state will be activated at end of
write even if no other data is loaded.
3.
Write Protect state will be deactivated at end of
write period even if no other data is loaded.
4.
1 to 64 bytes of data are loaded.
Software Data Protection
Disable Algorithm
Software Protected Write Cycle Waveforms
Notes:
1. A6 through A14 must specify the same page address during each high to low transition of WE (or CE) after the software
code has been entered.
2. OE must be high only when WE and CE are both low.
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA A0
TO
ADDRESS 5555
LOAD DATA XX
TO
ANY ADDRESS
(4)
LOAD LAST BYTE
TO
LAST ADDRESS
ENTER DATA
PROTECT STATE
WRITES ENABLED
(2)
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA 80
TO
ADDRESS 5555
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 20
TO
ADDRESS 5555
LOAD DATA XX
TO
ANY ADDRESS
(4)
LOAD LAST BYTE
TO
LAST ADDRESS
LOAD DATA 55
TO
ADDRESS 2AAA
EXIT DATA
PROTECT STATE
(3)