beautypg.com

Software product identification entry(1), Software product identification exit(1), Boot block lockout feature enable algorithm(1) – Rainbow Electronics AT49LV040 User Manual

Page 10: Software product identification entr y, Software product identification exi t, Boot block lockout feature enable algorit hm

background image

AT49BV/LV040

10

Software Product Identification Entry

(1)

Software Product Identification Exit

(1)

Notes:

1. Data Format: I/O7 - I/O0 (Hex);

Address Format: A14 - A0 (Hex).

2. A1 - A18 = V

IL

.

Manufacturer Code is read for A0 = V

IL

;

Device Code is read for A0 = V

IH

.

3. The device does not remain in identification mode if

powered down.

4. The device returns to standard operation mode.
5. Manufacturer Code: 1FH

Device Code: 13H

Boot Block Lockout Feature Enable
Algorithm

(1)

Notes:

1. Data Format: I/O7 - I/O0 (Hex);

Address Format: A14 - A0 (Hex).

2. Boot Block Lockout feature enabled.

LOAD DATA AA

TO

ADDRESS 5555

LOAD DATA 55

TO

ADDRESS 2AAA

LOAD DATA 90

TO

ADDRESS 5555

ENTER PRODUCT

IDENTIFICATION

MODE

(2)(3)(4)

EXIT PRODUCT

IDENTIFICATION

MODE

(4)

LOAD DATA AA

TO

ADDRESS 5555

LOAD DATA 55

TO

ADDRESS 2AAA

LOAD DATA F0

TO

ADDRESS 5555

OR

LOAD DATA F0

TO

ANY ADDRESS

EXIT PRODUCT

IDENTIFICATION

MODE

(4)

LOAD DATA AA

TO

ADDRESS 5555

LOAD DATA 55

TO

ADDRESS 2AAA

LOAD DATA 80

TO

ADDRESS 5555

LOAD DATA AA

TO

ADDRESS 5555

(2)

LOAD DATA 55

TO

ADDRESS 2AAA

LOAD DATA 40

TO

ADDRESS 5555

PAUSE 1 second