Dc and ac operating conditions for read operation, Ac characteristics for read operation – Rainbow Electronics AT27C800 User Manual
Page 4
AT27C800
4
Notes:
1. V
CC
must be applied simultaneously or before V
PP
, and removed simultaneously or after V
PP
.
2. V
PP
may be connected directly to V
CC
except during programming. The supply current would then be the sum of I
CC
and I
PP
.
Note:
2,3,4,5. See the AC Waveforms for Read Operation diagram.
DC and AC Operating Conditions for Read Operation
AT27C800
-90
-10
-12
-15
Operating
Temperature (Case)
Com.
0
°
C - 70
°
C
0
°
C - 70
°
C
0
°
C - 70
°
C
0
°
C - 70
°
C
Ind.
-40
°
C - 85
°
C -40
°
C - 85
°
C -40
°
C - 85
°
C
-40
°
C - 85
°
C
V
CC
Power Supply
5V
±
10%
5V
±
10%
5V
±
10%
5V
±
10%
DC and Operating Characteristics for Read Operation
Symbol
Parameter
Condition
Min
Max
Units
I
LI
Input Load Current
V
IN
= 0V to V
CC
±
1.0
µ
A
I
LO
Output Leakage Current
V
OUT
= 0V to V
CC
±
5.0
µ
A
I
PP1
(2)
V
PP
(1)
Read/Standby Current
V
PP
= V
CC
±
10
µ
A
I
SB
V
CC
(1)
Standby Current
I
SB1
(CMOS), CE = V
CC
±
0.3V
100
µ
A
I
SB2
(TTL), CE = 2.0 to V
CC
+ 0.5V
1.0
mA
V
CC
Active Current
f = 5MHz, I
OUT
= 0 mA,CE = V
IL
50
mA
V
IL
Input Low Voltage
-0.6
0.8
V
V
IH
Input High Voltage
2.0
V
CC
+ 0.5
V
V
OL
Output Low Voltage
I
OL
= 2.1 mA
0.4
V
V
OH
Output High Voltage
I
OH
= -400 mA
2.4
V
AC Characteristics for Read Operation
Symbol
Parameter
Condition
AT27C800
Units
-90
-10
-12
-15
Min
Max
Min
Max
Min
Max
Min
Max
t
ACC
(3)
Address to Output Delay
CE = OE = V
IL
90
100
120
150
ns
t
CE
(2)
CE to Output Delay
OE = V
IL
90
100
120
150
ns
t
OE
(2,3)
OE to Output Delay
CE = V
IL
40
40
40
50
ns
t
DF
(4,5)
OE or CE High to Output Float, whichever
occured first
30
30
35
40
ns
t
OH
(4)
Output Hold from Address CE or OE,
whichever occured first
5.0
5.0
5.0
5.0
ns
t
ST
BYTE High to Output Valid
90
100
120
150
ns
t
STD
BYTE Low to Output Transition
40
40
50
60
ns
Preliminary Information