2 Basic Operations
2.1 Command Syntax
In the next paragraphs the following notations are used:
represents the Carriage Return Character (13)
represents the Line Feed Character (10)
represents a parameter whatever name is in place of the xx. (< and > characters are
only for delimiting the parameter and must not be issued to the terminal).
[
characters are only for delimiting the optional parameter and must not be issued to the
terminal).
2.1.1 Interface Style
The GE863-GPS module is using an AT interface that is defined in the document
80000S T10025a
(AT Commands Reference Guide). The specification defines 3 possible AT interfaces:
0 - AT command interface of the products, to the GM862-GSM and GM862-GPRS interface style
1 – AT interface of the products, to the GM862-PCS, PYTHON, QUAD-PY, TRIZIUM and GE863-
QUAD, PY interface style
2 - switches the AT command interface style of the product, to the new products like GE864, GC864
and the GPS products
The default interface for the GE863-GPS product is 2.
The switch between the different interfaces could also be performed with the #SELINT AT command.
Refer to the AT Commands Reference Guide for the full command description.
All the AT commands described in this specification is related to SELINT 2