Table 3. i, C slave addresses – Rainbow Electronics MAX9135 User Manual
Page 12
MAX9132/MAX9134/MAX9135
Programmable, High-Speed, Multiple
Input/Output LVDS Crossbar Switches
12
______________________________________________________________________________________
multiple data bytes are transmitted before a STOP con-
dition is detected, these bytes are generally stored in
subsequent MAX9132/MAX9134/MAX9135 internal reg-
isters because the command byte address generally
autoincrements (Table 1).
Data Format for Reading from the Slave
The MAX9132/MAX9134/MAX9135 are read using the
devices’ internally stored command bytes as an
address pointer, the same way the stored command
byte is used as an address pointer for a write. The
pointer does not autoincrement after each data byte is
read. Initiate a read by writing the command byte to the
proper slave address (Figure 2), then send the device’s
slave address with the R/
W bit set to 1. The slave now
responds with the contents of the requested register
(Figure 2).
LIN Interface
The LIN interface is a low-speed, low-cost interface used
in slow control signal traffic in automotive applications.
This device is the slave node in the LIN bus cluster and
is designed based on the LIN Rev. 1.3 specification. The
LIN master sends data to the MAX9132/MAX9134/
FRAME SLOT
FRAME
RESPONSE
SPACE
INTER-
FRAME
SPACE
RESPONSE
HEADER
BREAK
SYNC
PROTECTED
INDENTIFIER
TRANSMITTED
FROM MASTER
TRANSMITTED
FROM A MASTER OR SLAVE
*N = 2 FOR WRITE
AND 4 FOR READ
DATA 1
DATA 2
DATA N*
CHECKSUM
Figure 3. LIN Bus Signal Format
READ FORMAT
WRITE FORMAT
0x00
0x01
0x01
DATA 1
DATA 2
DATA 1
DATA 2
DATA 3
DATA 4
0x02
0x02
0xFF
Figure 4. LIN Write and Read Data Frame
PIN
ADDRESS
AS0
AS1
A[7:5]
A4
A3
A2
A1
A0
ADDRESS (HEX)
Low
Low
101
0
0
0
0
R/
W
0xA0
Low
Open
101
0
0
0
1
R/
W
0xA2
Low
High
101
0
0
1
0
R/
W
0xA4
Open
Low
101
0
0
1
1
R/
W
0xA6
Open
Open
101
0
1
0
0
R/
W
0xA8
Open
High
101
0
1
0
1
R/
W
0xAA
High
Low
101
0
1
1
0
R/
W
0XAC
High
Open
101
0
1
1
1
R/
W
0xAE
High
High
101
1
0
0
0
R/
W
0xB0
Table 3. I
2