Battery measurement, Table 34. jack detection registers (cont, Table 35. battery measurement registers – Rainbow Electronics MAX98089 User Manual

Page 116: Table 34. jack detection registers (continued)

background image

��������������������������������������������������������������� Maxim Integrated Products 116

MAX98089

Low-Power, Stereo Audio Codec

with FlexSound Technology

Table 35. Battery Measurement Registers

Battery Measurement

The IC measures the voltage applied to SPKLVDD (typically the battery voltage) and reports the value in register 0x03.
This value is also used by the speaker limiter circuitry to set accurate thresholds. When the battery measurement func-
tion is disabled, the battery voltage is user programmable.

Table 34. Jack Detection Registers (continued)

REGISTER

BIT

NAME

DESCRIPTION

0x03

4

VBAT

Battery Voltage
Read VBAT when V

BATEN

= 1 to determine V

SPKLVDD

. Program VBAT when V

BATEN

=

0 to allow proper speaker amplifier signal processing. Calculate/program the battery
voltage using the following formula:
V

BATTERY

= 2.55V + [VBAT/10]

3
2
1
0

0x51

7

SHDN

See the Power Management section.

6

VBATEN

Battery Measurement Enable. Enables an internal ADC to measure V

SPKLVDD

.

0 = Disabled (register 0x03 readable and writeable)
1 = Enabled (register 0x03 read only)

3

PERFMODE

See the Power Management section.

2

HPPLYBCK

See the Power Management section.

1

PWRSV8K

See the Power Management section.

0

PWRSV

See the Power Management section.

REGISTER

BIT

NAME

DESCRIPTION

0x4E

7

BGEN

See the Power Management section.

6

SPREGEN

See the Power Management section.

5

VCMEN

See the Power Management section.

4

BIASEN

See the Power Management section.

0

JDWK

JACKSNS Pullup
When JDWK = 1, JACKSNS is slow to increase in voltage. Set JDWK = 0 before setting
JDETEN = 1 to prevent false detection.
Valid when MBIAS = 0.
0 = 2.4kI to SPKLVDD (allows microphone detection)
1 = 5FA to SPKLVDD (minimizes supply current)