Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-1895 User Manual
Page 53

7. Troubleshooting
PNEG-1895 V2 Electronic Distributor Control
53
Figure 7D
Cause: This message will appear if the user attempts to enter a position location value that is outside the
range of values allowed by the controller. This range exists to protect the equipment. To prevent this
message, user should enter a value that is within the range of values displayed in the error message.
(These values will vary for each controller; the values shown
will not be representative of
all configurations.)
Figure 7E
Cause: This message will appear if the controller has sensed that the spout has drifted from its desired
position while not being commanded to move. This may be caused by mechanical lash within the drive
mechanism or by the use of the manual key switch override on the front of the panel. User should execute
a “Move” command (see moving positions
) before attempting to move material through
distributor. Controller should force a homing operation before completing the move command.
Figure 7F
Cause: This message will be displayed if the user attempts to select the position where the distributor is
currently located to be locked-out. If this position is desired for lock-out, a “Move” command (see moving
positions
) should be performed to change to another position before selecting the position
for lock-out.