Note:
When carrying out switching point adjustments keep in mind that there
is a switching delay of 0.5 sec between the moment when the
switching point is reached and the moment when the switching
function is triggered. The potentiometer must therefore be turned
slowly.
A possible additional switching delay should only be switched on after
the adjustment.
Control lamps (LED) in the front plate indicate operation, switching
status and fault signal.
TOR
149A
ON
3
4
1
2
Fig. 15: Control lamps in the instrument front (C)
1
Control lamp - Operating voltage - green (gn)
2
Control lamp - Fault signal - red (rd)
3
Control lamp - Switching status channel 2 - yellow (ye)
4
Control lamp - Switching status channel 1 - yellow (ye)
l
Green (gn)
-
Operating control lamp
-
Mains voltage on, instrument is operating
l
Red (rd)
-
Failure lamp
-
Fault on the sensor circuit due to sensor failure or line break
-
If the fail safe relay is deenergized, the red failure lamp will
light
l
Yellow (ye)
-
Relay control lamps
-
The yellow relay control lamps react depending on the set
mode (min./max.)
-
The relay control lamp generally indicates the activated
(energized) condition of the relay
-
A dark relay control lamp means that the relay is deenergised
Signal lamps (C)
VEGATOR
632 • Signal conditioning instrument
21
6 Adjustment elements
35243
-EN
-120228