beautypg.com

E. measuring resistance, Instrument set-up, Measurement procedure – Test Products International 440 User Manual

Page 20: Optional dmm functions (refer to page 27), Prog (refer to page 27), Optional d mode functions (refer to page 29)

background image

21

19

e.

Measuring Resistance

WARNING!

Do not attempt to make resistance measurements with
circuit energized. For best results, remove resistor
completely from circuit before attempting to measure it.

NOTE:
To make accurate low ohm measurements, short the
ends of the test leads together and record the resistance
reading. Deduct this value from actual readings.

Instrument set-up:

FUNCTION

BLACK RED

MINIMUM

MAXIMUM

TEST LEAD TEST LEAD

READING

READING

COM

V

0.1

30.00M

Measurement Procedure:

1.

Disconnect power to circuit to be measured.

2.

Plug black test lead into the COM input jack.

3.

Plug red test lead into V

Ω input jack.

4.

Set the rotary switch on the 440 to the

function.

5.

Connect the test leads to the circuit to be measured.

6.

Read the resistance value on the 440.

!

Optional DMM Functions (refer to page 27)

REL

FULL

AUTO

F1

F2

F3

F4

F5

PROG (refer to page 27)

REC

REL%

COMP

EDIT

EXIT

F1

F2

F3

F4

F5

Optional D Mode Functions (refer to page 29)

METER

TREND

EXIT

F1

F2

F3

F4