E. measuring resistance, Instrument set-up, Measurement procedure – Test Products International 440 User Manual
Page 20: Optional dmm functions (refer to page 27), Prog (refer to page 27), Optional d mode functions (refer to page 29)
21
19
e.
Measuring Resistance
WARNING!
Do not attempt to make resistance measurements with
circuit energized. For best results, remove resistor
completely from circuit before attempting to measure it.
NOTE:
To make accurate low ohm measurements, short the
ends of the test leads together and record the resistance
reading. Deduct this value from actual readings.
Instrument set-up:
FUNCTION
BLACK RED
MINIMUM
MAXIMUM
TEST LEAD TEST LEAD
READING
READING
Ω
COM
V
Ω
0.1
Ω
30.00M
Ω
Measurement Procedure:
1.
Disconnect power to circuit to be measured.
2.
Plug black test lead into the COM input jack.
3.
Plug red test lead into V
Ω input jack.
4.
Set the rotary switch on the 440 to the
Ω
function.
5.
Connect the test leads to the circuit to be measured.
6.
Read the resistance value on the 440.
!
Optional DMM Functions (refer to page 27)
REL
FULL
AUTO
F1
F2
F3
F4
F5
PROG (refer to page 27)
REC
REL%
COMP
EDIT
EXIT
F1
F2
F3
F4
F5
Optional D Mode Functions (refer to page 29)
METER
TREND
EXIT
F1
F2
F3
F4
F5