beautypg.com

A. measuring dc volts (v), Instrument set-up, Measurement procedure – Test Products International 440 User Manual

Page 16: Optional dmm functions (refer to page 27), Prog (refer to page 27), Optional d mode functions (refer to page 29)

background image

17

15

a. Measuring DC Volts (V)

CAUTION!
Do not attempt to make a voltage measurement if a test
lead is plugged in the A or µmA input jack. Instrument
damage and/or personal injury may result.

WARNING!

Do not attempt to make a voltage measurement of more
than 1000V or of a voltage level that is unknown.

Instrument set-up:

FUNCTION

BLACK RED

MINIMUM

MAXIMUM

TEST LEAD

TEST LEAD

READING

READING

V

COM

V

0.1mV

1000V

Measurement Procedure:

1.

Disconnect power to circuit to be measured.

2.

Plug black test lead into COM input jack.

3.

Plug red test lead into the V

Ω input jack.

4.

Set the rotary switch to the V function.

5.

Connect test leads to circuit to be measured.

6.

Reconnect power to circuit to be measured.

7.

Read the voltage on the 440.

!

Optional DMM Functions (refer to page 27)

REL

PEAK

FREQ

PERI

FULL

HOLD

AUTO

F1

F2

F3

F4

F5

PROG (refer to page 27)

REC

REL%

COMP

EDIT

EXIT

F1

F2

F3

F4

F5

Optional D Mode Functions (refer to page 29)

COMBO

METER

SCOPE

TREND

EXIT

F1

F2

F3

F4

F5