Po wer/ener g y monit oring, Companion current transformers, Dimensional drawings – Veris Industries H84xxVBS SERIES Datasheet User Manual

Page 2: Accessories, Data outputs ordering information

background image

p

o

wer/ener

g

y monit

oring

800.354.8556

+1 503.598.4564

www.veris.com

H681

(Model/Amps)

Small:

0-100 = 100A

0-200 = 200A

0-300 = 300A

Medium:

1-400 = 400A

1-600 = 600A

1-800 = 800A

Large:

2-800 = 800A

2-1600 = 1600A

2-2000 = 2000A

2-2400 = 2400A

-

(Output Type)

= 0-1VAC

Example:

H681 2-800 – 1V

COMPANION CURRENT TRANSFORMERS

1V

MODEL

DESCRIPTION

DATA OUTPUT

DISPLAY SCREENS

PANEL MOUNT - 120-480V
(For Control Voltages > 415VAC to
600VAC order H84xxVBS)

Pulse

Modbus

FDS

EDS

H8463V* Panel Mount, 1V, CT Input, FDS

n

n

H8453V* Panel Mount, 1V, CT Input, FDS

n

n

H8436V

Panel Mount, 1V, CT Input, FDS

n

n

H8437V

Panel Mount, 1V, CT Input, EDS

n

n

WALL MOUNT - 120-480V
(For Control Voltages > 415VAC
to 600VAC order H84xxVBS)

Pulse

Modbus

FDS

EDS

H8463VB* Wall Mount, 1V, CT Input, FDS

n

n

H8453VB* Wall Mount, 1V, CT Input, FDS

n

n

H8436VB

Wall Mount, 1V, CT Input, FDS

n

n

H8437VB

Wall Mount, 1V, CT Input, EDS

n

n

WALL MOUNT - 240-600V

Pulse

Modbus

FDS

EDS

H8463VBS* Wall Mount, 1V, CT Input, FDS, 240-600V

n

n

H8453VBS* Wall Mount, 1V, CT Input, FDS, 240-600V

n

n

H8436VBS

Wall Mount, 1V, CT Input, FDS, 240-600V

n

n

H8437VBS

Wall Mount, 1V, CT Input, FDS, 240-600V

n

n

H8437: Extended Data Set (EDS)

(FDS Plus):

Amps, Current Neutral

Frequency

kVAh, Consumption

kVARh, Consumption

Minimum Real power

Maximum Real power

KVA, Apparent Power, Per Phase

KVAR, Reactive Power, Per Phase

KW, Total Real Power Present Demand

KVA, Total Apparent Power Present Demand

KVAR, Total Reactive Power Present Demand

KW, Total Real Power Max Demand

KVA, Total Apparent Power Max Demand

KVAR, Total Reactive Power Max Demand

THD, Voltage A-N, B-N, C-N

THD, Voltage A-B, B-C, A-C

THD, Current, Per Phase

Usage Hours

Usage Minutes

Total Hours

Total Minutes

H8436:

Full Data Set (FDS)

kWh, Consumption

kW, Real Power

kVAR, Reactive power

kVA, Apparent power

Power factor

Voltage, line to line

Voltage, line to neutral

Amps, Average current

kW, Real power ØA

kW, Real power ØB

kW, Real power ØC

Power factor ØA

Power factor ØB

Power factor ØC

Voltage, ØA to ØB

Voltage, ØB to ØC

Voltage, ØA to ØC

Voltage, ØA to Neutral

Voltage, ØB to Neutral

Voltage, ØC to Neutral

Amps, Current ØA

Amps, Current ØB

Amps, Current ØC

DIMENSIONAL DRAWINGS

+0.8

–0.0

2"

0.8"

(19 mm)

(50 mm)

3.9"

(96 mm)

3.9"

(96 mm)

(92 mm)

3.6"

(92 mm)

+0.8

–0.0

3.6"

H8400 SERIES

4.1"

(104 mm)

9.1"

(242 mm)

8.3"

(210 mm)

H84xxV

H84xxVB(S)

ACCESSORIES

Fuse Kits (AH02, AH03, AH04)
DIN Rail Mounting Kit (AH23)
Modbus-to-BACnet Converter (E8950)
Modbus TCP Gateway (U013-0012)

DATA OUTPUTS

ORDERING INFORMATION

AH23

AH04

The H8453 has two normally open solid-state outputs: one kWh and one field selectable for phase loss or kVARh. The

H8463 has one normally open output (kWh) and one normally closed output (field selectable for phase loss or kVAR).

U013-0012

E8950