Veris Technologies pH Manager - Operating Instructions User Manual
Page 35
Pub.# OM17-MSP-pH
4-6
Figure 8
• Pinch point hazard: to prevent injury, stand clear when raising or lowering any part of the Veris
MSP. Disengage automatic cycling function before working around unit. Install all transport locks
before transporting or working underneath.
Three-point Mounted Units
Raise sampling mechanism to full height. Begin depth adjustment process with shank in center
position (pin in one of two center holes). Adjust ratchet jack so that coulters will penetrate 1-
2”
deep
– 21” pin-to-pin is a good starting point Adjust three-point top link to level unit when in soil.
Figure 9 a,b,c
Manual-Auto switch:
must be in Automatic
mode for mapping;
in Manual mode for
manual control of
washing or sampler
shoe position
Wash: On when washing
manually; Must be Off
for Automatic washing
Sampler up and down:
raises sampler shoe
manually
Begin with a
dimension of
21” pin to pin
Adjust tractor or
implement top link to
level
Power switch
must be on to
operate any
function
Center position
Initial adjustment of 21”
Adjust top link to
level in soil