beautypg.com

Capacity, We’ve got the power – Power-Sonic Sealed Lead Acid Batteries - Technical Manual User Manual

Page 8

background image

Capacity

Capacity, expressed in ampere-hours (AH), is the

product of the current discharged and the length of

discharge time. The rated capacity (C) of a Power-

Sonic battery (PS, PSH and PSG-Series) is measured

by its performance over 20 hours of constant current

discharge at a temperature of 20°C (68°F) to a cut

off voltage of 1.75 volts/cell.

As an example, model PS-610, with a rated capacity of

1.1 AH will deliver 55mA (1/20 of 1.1 AH, or 0.05C) for

20 hours before the voltage reaches an end voltage of

5.25 volts.

By cycling the battery a few times or float charging

it for a month or two, the highest level of capacity

development is achieved. Power-Sonic batteries

are fully charged before leaving the factory, but full

capacity is realized only after the battery has been

cycled a few times or been on float charge for some

time.

When a battery discharges at a constant rate, its

capacity changes according to the amperage load.

Capacity increases when the discharge current is less

than the 20 hour rate and decreases when the current

is higher.

Rated

Capacity

20 Hour Rate

10 Hour Rate

5 Hour Rate

1 Hour Rate

Amps

AH

Amps

AH

Amps

AH

Amps

AH

28.0 AH

1.50

30.00

2.80

28.00

5.10

25.50

18.60

18.60

35.0 AH

1.80

36.00

3.50

35.00

6.50

32.50

27.00

27.00

42.0 AH

2.25

45.00

4.20

42.00

7.20

36.00

25.20

25.20

56.0 AH

3.00

60.00

5.60

56.00

9.50

47.50

33.00

33.00

65.0 AH

3.53

70.60

6.50

65.00

11.20

56.00

39.00

39.00

75.0 AH

4.00

80.00

7.50

75.00

12.90

64.50

45.00

45.00

92.0 AH

4.90

98.00

9.20

92.00

15.80

79.00

55.20

55.20

103.0 AH

5.55

111.00

10.30

103.00

17.70

88.50

61.80

61.80

124.0 AH

6.45

129.00

12.40

124.00

21.30

106.50

74.40

74.40

144.0 AH

7.70

154.00

14.40

144.00

24.08

120.40

84.00

84.00

153.0 AH

8.30

166.00

15.30

153.00

26.30

131.50

91.80

91.80

210 0 AH

11.30

226.00

21.00

210.00

36.10

180.50

126.00

126.00

Table : PG-Series batteries, by industry convention, are rated at their 0 hour rate.

Table 3 shows capacities for various multiples of the 20-hour discharge current for PG models.

We’ve Got The Power.