Power-Sonic PG-12v6 User Manual
Pg range, Pg12v6, 6yr design life in float service at 20 º c)
PG Range
Discharge Characteristics (25ºC, 77ºF)
Physical Specification
Internal Resistance mΩ
Dimensions (mm)
Standard terminal (mm)
Power-Sonic Europe Limited
3 Buckingham Square, Wickford, Essex, SS11 8YQ
Tel: +44 (0)1268 560686 Fax: +44 (0)1268 560902
www.power-sonic.co.uk
PG12V6
Nominal Voltage
Nominal Capacity
12V
6.0 AH
Dimension
Length
Width
Container Height
Total Height (with terminal)
Weight
Standard Terminal
F2 (standard)
Approx 1.8kg
90
70
101
107
2 mm
2 mm
2 mm
2 mm
+
-
+
-
+
+
-
Rated
Capacity
Capacity
Affected by
Temperature
Cycle
Standby
C
on
st
ant
V
ol
ta
g
e
C
harg
e
Initial Charging Current
Less than 1.5A
Voltage 14.4V ~ 15.0V
at 25°C (77°F)
Recommended Charge
Current less than 1.5A
Voltage 13.5V ~
13.8V at 15°C (77°F)
40°C (104°F)
25°C (77°F)
0°C (32°F)
103%
100%
86%
90
2
101
2
107
2
-
+
72 2
70
2
F2
4.75(6.35)
6.35(7.95)
3.2 (3.4)
0.8
25.0 mΩ
Rev2 03/12
(6yr Design Life in Float Service at 20ºC)
20hRate(1.80V/cell) 6.00AH
10hRate(
5.60AH
1.80V/cell)
5hRate(
5.10AH
175V/cell)
3hRate(
4.59AH
1.75V/cell)
1hRate(
3.77AH
1.60V/cell)
F.V/Time
5min
10min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
11.40
8.77
7.27
6.28
4.86
3.58
3.02
1.78
1.40
1.14
0.93
0.80
0.65
0.54
0.30
1.80V/cell
15.30
11.20
8.78
7.43
5.73
4.16
3.38
1.95
1.50
1.21
0.99
0.86
0.69
0.56
0.30
1.75V/cell
17.30
12.30
9.59
7.99
5.95
4.32
3.54
2.02
1.53
1.24
1.02
0.89
0.70
0.57
0.30
1.70V/cell
19.00
13.40
10.20
8.40
6.20
4.49
3.65
2.07
1.57
1.27
1.05
0.90
0.71
0.58
0.31
1.65V/cell
21.00
14.50
10.90
8.92
6.54
4.61
3.73
2.10
1.64
1.32
1.07
0.92
0.72
0.60
0.31
1.60V/cell
23.20
15.70
11.60
9.50
6.90
4.80
3.77
2.19
1.69
1.36
1.11
0.94
0.73
0.60
0.31
Constant Current Discharge (Amperes) at 25 °C (77°F )
F.V/Time
5min
10min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
20.90
16.20
13.60
11.80
9.26
6.88
5.82
3.47
2.72
2.22
1.82
1.58
1.28
1.07
0.59
1.80V/cell
27.70
20.50
16.20
13.80
10.80
7.94
6.48
3.76
2.91
2.36
1.94
1.69
1.35
1.10
0.59
1.75V/cell
30.60
22.10
17.40
14.70
11.10
8.16
6.75
3.88
2.95
2.40
1.98
1.73
1.37
1.13
0.60
1.70V/cell
32.80
23.60
18.40
15.30
11.50
8.46
6.94
3.97
3.03
2.46
2.03
1.76
1.39
1.15
0.61
1.65V/cell
35.60
25.20
19.40
16.20
12.00
8.59
7.05
4.00
3.15
2.54
2.08
1.79
1.41
1.17
0.62
1.60V/cell
38.40
26.70
20.40
17.00
12.60
8.90
7.08
4.16
3.23
2.61
2.14
1.83
1.42
1.19
0.62
Constant Power Discharge (Watts/cell) at 25°C (77°F )
In the event of further technical development we reserve the right to alter our design, specification and price without notice. E&O.E