Power-Sonic PS-12120 User Manual

Ps range, 5yr design life in float service at 20°c)

background image

PS Range

Discharge Characteristics (25ºC, 77ºF)

Physical Specification

Internal Resistance mΩ

Dimensions (mm)

Standard terminal (mm)

PS-12120 12V 12AH

Nominal Voltage

Nominal Capacity (20HR)

12V

12.0 AH

Dimension

Length

Width

Container Height

Total Height (with terminal)

Weight

Standard Terminal

F1

Approx 3.60kg

151

98

95

101

2 mm

2 mm

2 mm

2 mm

+

-

+

-

+

+

-

Rated

Capacity

Capacity

Affected by

Temperature

Cycle

Standby

Cons

tant V

olt

a

g

e

Charg

e

Initial Charging Current
Less than 3.0A
Voltage 14.40V ~ 15.0V
at 25°C (77°F)

Recommended Charge
Current less than 3.0A
Voltage 13.5V ~
13.8V at 25°C (77°F)

40°C (104°F)

25°C (77°F)

0°C (32°F)

103%

100%

86%

4.75

6.35

3.2

0.8

F1

98

2

151

2

95

2

101

2

+

-

14.0 mΩ

Power-Sonic Europe Limited

3 Buckingham Square, Wickford, Essex, SS11 8YQ

Tel: +44 (0)1268 560686 Fax: +44 (0)1268 560902

[email protected]

www.power-sonic.co.uk

Rev6 - 07-13

-

(5yr Design Life in Float Service at 20°C)

In the event of further technical development we reserve the right to alter our design, specification and price without notice. E&O.E

20hRate(1.80V/cell) 12.00AH
10hRate(1.80V/cell) 11.20AH
5hRate(

) 10.20AH

1.75V/cell

3hRate(

) 9.18AH

1.75V/cell

1hRate(

) 7.54AH

1.60V/cell

F.V/Time

5min

10min

15min

20min

30min

45min

1h

2h

3h

4h

5h

6h

8h

10h

20h

1.85V/cell

22.9

17.5

14.5

12.6

9.72

7.16

6.03

3.57

2.79

2.27

1.85

1.61

1.30

1.08

0.594

1.80V/cell

30.7

22.4

17.6

14.9

11.5

8.33

6.76

3.90

3.00

2.42

1.99

1.72

1.37

1.12

0.600

1.75V/cell

34.6

24.6

19.2

16.0

11.9

8.64

7.07

4.04

3.06

2.48

2.04

1.77

1.40

1.15

0.606

1.70V/cell

38.1

26.9

20.5

16.8

12.4

8.99

7.29

4.14

3.15

2.54

2.09

1.81

1.42

1.17

0.617

1.65V/cell

42.0

29.0

21.8

17.8

13.1

9.21

7.46

4.20

3.28

2.63

2.15

1.85

1.44

1.19

0.625

1.60V/cell

46.3

31.5

23.3

19.0

13.8

9.60

7.54

4.38

3.38

2.71

2.22

1.89

1.45

1.21

0.629

Constant Current Discharge (Amperes) at 25°C (77°F)

F.V/Time

5min

10min

15min

20min

30min

45min

1h

2h

3h

4h

5h

6h

8h

10h

20h

1.85V/cell

41.8

32.4

27.1

23.7

18.5

13.8

11.6

6.93

5.44

4.44

3.63

3.16

2.56

2.14

1.18

1.80V/cell

55.5

40.9

32.3

27.6

21.5

15.9

13.0

7.51

5.82

4.71

3.88

3.37

2.71

2.21

1.19

1.75V/cell

61.2

44.3

34.9

29.4

22.2

16.3

13.5

7.76

5.91

4.80

3.97

3.46

2.75

2.26

1.20

1.70V/cell

65.6

47.1

36.7

30.7

22.9

16.9

13.9

7.94

6.06

4.92

4.06

3.52

2.78

2.31

1.22

1.65V/cell

71.3

50.4

38.7

32.3

24.0

17.2

14.1

8.01

6.29

5.07

4.16

3.59

2.82

2.35

1.23

1.60V/cell

76.8

53.5

40.8

34.1

25.2

17.8

14.2

8.31

6.45

5.21

4.28

3.65

2.84

2.37

1.24

Constant Power Discharge (Watts/cell) at 25°C (77°F)

Table of contents