beautypg.com

Power-Sonic PHR-12200 User Manual

12 volt 58 ah, 225 w/cell, Hr. rate

background image

HT

H

W

L

M6

016

3

Physical Dimensions: in (mm)

Features

• Superb high-rate discharge characteristics that ensure reliable

performance in UPS applications for up to 10 years. UL recognized

• Flame retardant ABS case and cover to UL 94 V-O for superior

performance

• VRLA Absorbent Glass Mat (AGM) Technology guarantees safe

operation without maintenance and “non-restricted article” status for

transportation. Approved for transport by air. D.O.T., I.A.T.A. and

F.A.A. certified.

• Precision plate pasting for higher consistency with 100% load

testing to ensure uniform capacity

• Patented dual-paste process for enhanced active material bonding,

and computer guided volumetric electrolyte control for precision

filling

• Lead-calcium alloy grids and the use of high purity lead account for

superior shelf-life characteristics

Performance Specifications

Nominal Voltage ............................................... 12 volts (6 cells)
Nominal Power (15 min.) ......................................225 W/Cell
Rated Capacity
20-hr. (2.90A to 10.80 volts) ...................................... 58.0 AH
10-hr. (5.50A to 10.50 volts) ...................................... 55.0 AH
8-hr. (6.68A to 10.50 volts) ...................................... 53.6 AH
Approximate Weight .................................. 38.1 lbs. (17.3 kg)
Internal Resistance (approx.) ................................ 5 milliohms
Max Discharge Current (5 Sec.) ......................... 825 amperes
Charging Voltage @ 77°F (20° C)
Standby Use ............. 2.275 ± 0.025 V/Cell, (-3.3mV/°C/Cell)
Cycle Use .......................... 2.45±0.05 V/Cell, (-5 mV /°C/Cell)
Maximum Charging Current ........................................ 16.5 A
Case....... ........................... Flame Retardant ABS Plastic (UL 94 V-O)

PHR-12200

L: 9.02 (229) W: 5.43 (138) H: 7.87 (200) HT: 7.99 (203)

12 Volt 58 AH

@ 20-hr. rate

225 W/Cell

@ 15-min. rate

Constant Current Discharge (Amperes) at 25ºC

Constant Power Discharge (Watts/Cell) at 25ºC (Blue)

www.power-sonic.com

To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website.

All data subject to change without notice.

Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions.

PHR-12200

5 min

10 min

15 min

20 min

30 min

45 min

1h

2h

3h

4h

5h

6h

8h

10h

20h

1.85V

111.4

77.6

64

55.6

44.6

34.2

28

17.12

13.04

10.72

9.1

7.88

6.26

5.2

2.88

1.80V

13.7

92.6

74.2

62.8

49.4

37.4

30.2

18.18

13.7

11.26

9.48

8.22

6.5

5.4

2.9

1.75V

162.2

104.8

81.8

68.4

52.6

39.6

31.8

18.96

14.2

11.62

9.74

8.42

6.68

5.5

2.92

1.70V

184

115.6

88.6

73.4

55.4

41.2

33

19.74

14.66

11.9

9.98

8.64

6.78

5.6

2.98

1.67V

202

124.2

93.8

77

57.6

42.8

34.4

20.4

15.02

12.16

10.2

8.8

6.88

5.66

3.02

1.60V

212

129.4

97.6

79.6

59.2

43.8

35.2

21

15.38

12.46

10.42

8.98

7.02

5.76

3.04

1.85V

262.3

196.5

166.3

143.9

110.9

81.1

65.0

38.5

27.7

21.9

18.3

15.8

12.6

10.5

5.46

1.80V

308.7

221.1

186.4

157.0

118.1

85.3

68.0

39.9

28.6

22.5

18.8

16.2

12.9

10.8

5.65

1.75V

353.2

242.4

199.6

166.5

122.7

88.3

70.0

41.0

29.2

22.9

19.0

16.4

13.1

10.9

5.75

1.70V

378.4

261.2

211.5

175.2

127.6

90.6

71.8

41.4

29.7

23.3

19.3

16.7

13.3

11.0

5.81

1.67V

406.6

274.0

225.1

183.2

131.4

93.3

73.7

42.3

30.0

23.6

19.6

16.9

13.4

11.2

5.89

1.60V

432.7

289.8

232.3

189.0

134.8

95.6

75.2

42.7

30.4

24.0

20.0

17.2

13.6

11.3

5.98