Dialog 4224 Operator

Other Useful Features

Alarm

If a fault occurs in the exchange, the alarm lamp flashes.
Use the following procedure to acknowledge the alarm:

Ц

Ф

Alarm

Press and hold while reading the display.

The bottom right hand corner of the display shows 2, 3 or 4. The

number indicates the degree of seriousness:
2 = Requires action within one week
3 = Requires immediate action during normal working hours
4 = Demands immediate action at all times
The purpose with the acknowledgement of the alarm is to avoid

other operators from reporting the alarm. After acknowledgement,

you must report the alarm to maintenance, stating the alarm class

as above.
When the Alarm key is released, the key lamp changes to steady

light. This indicator remains until maintenance staff have eliminated

the fault and erased the alarm from the maintenance terminal.
If you press the Alarm key while the lamp shows steady light,

EXG

SERV

is displayed in the bottom right corner indicating that the

exchange is being repaired.

Emergency mode

It is possible to set the exchange into Emergency mode. This only

allows predetermined extensions to initiate calls.
To set the exchange into Emergency mode:

*90#

Dial.

EXG EMER

is shown in the upper right corner of the display.

To return the exchange to normal state:

#90#

Dial.