beautypg.com

Figure 3-8. example power supply outputs, Figure 3-8 example power supply outputs, Operation – American Magnetics 4Q1005PS-430 Integrated Power Supply System User Manual

Page 64

background image

46

Rev. 5

Operation

Setup Menu : Supply

the keypress. Power supply selection should also preferably be

performed with the power supply off for maximum safety.

The power supply settings define the output voltage and current

ranges for a specific power supply. For example, V-I diagrams are

presented in Figure 3-8 for the AMI 12100PS and AMI 4Q06125PS

selections. The AMI 12100PS operates as a one-quadrant system

without the addition of an energy absorber. As shown in the

diagram, with the addition of an AMI Model 601 energy absorber,

the AMI 12100PS system can function as a two-quadrant supply

providing +5 V to -5 V at the power supply system output

terminals. The AMI 4Q06125PS power supply operates as a four-

quadrant power supply without the addition of an energy absorber.

The addition of an energy absorber to the system does not change

the capabilities of the power supply itself (or the values entered for

the supply). The addition of an energy absorber does, however,

change the system operating ranges per the example of Figure 3-8.

3.10.1.1.1 Custom... Picklist Item

Custom... is a unique Select Supply picklist item. When selected, it

opens a deeper submenu in which the custom power supply

parameters (Min Output Voltage, Max Output Voltage, Min Output

Current, Max Output Current and V-V Mode Input Range) are

entered. Entry of each of these parameters is described below.

Figure 3-8.

Example Power Supply Outputs