A.7 ethernet connector, A.8 rs-232 connector, Table a-7. rs-232 connector pin definitions – American Magnetics 4Q1005PS-430 Integrated Power Supply System User Manual
Page 171: Table a-6, Ethernet rj-45 connector pin definitions, Table a-7, Rs-232 connector pin definitions, Appendix
Rev. 5
153
Appendix
RS-232/422 Connector
A.7
Ethernet Connector
A.8
RS-232 Connector
The RS-232 connector is a standard DTE 9-pin D-sub male connector
Table A-6.
Ethernet RJ-45 Connector Pin Definitions
Pin
Mnemonic
Function
1
TXD+
Transmit differential output +
2
TXD—
Transmit differential output —
3
RXD+
Transmit differential input +
4
not used
5
6
RXD—
Transmit differential input —
7
not used
8
Table A-7.
RS-232 Connector Pin Definitions
Pin
Mnemonic
Function
1
DCD
Data Carrier Detect
2
RXD
Receive Data
3
TXD
Transmit Data
4
DTR
Data Terminal Ready
5
GND
Signal Ground
6
DSR
Data Set Ready
7
RTS
Request To Send
See also other documents in the category American Magnetics Equipment:
- 12200PS DC Power Supply (CE-Marked) (58 pages)
- MAxes Multi-Axis Magnet systems for Vector Fields (4 pages)
- 05200PS-430-601 High Stability Integrated Power Supply System (226 pages)
- Current Leads for Cryogenic Systems Brochure (8 pages)
- 150A Portable Liquid Helium Level Meter (CE-Marked) (7 pages)
- AMI Liquid Helium Level Sensors (7 pages)
- 12100PS DC Power Supply (CE-Marked) (53 pages)
- 187 Self-Compensating Liquid Level Controller (75 pages)
- 286 Multi-Sensor Liquid Level Instrument (CE-Marked) (116 pages)
- 601 Energy Absorber (CE-Marked) (7 pages)
- 05100PS-430-601 Integrated Power Supply System (224 pages)
- 4Q06125PS-430 Integrated Power Supply System (216 pages)
- SVTI-CH6022-2 (2 pages)
- OPMX-141-1 (2 pages)
- 05500PS-430-601 High Stability Integrated Power Supply System (228 pages)
- 188CPS Point-Sensing Instrument (29 pages)
- MX-4.5_9-30 (2 pages)
- 4Q05100PS Four-Quadrant Power Supply (7 pages)
- AMI Superconducting Magnets (25 pages)
- Current Leads for Cryogenic Systems Manual (10 pages)
- SD-6-15 (2 pages)
- CRYOGEN FREE SUPERCONDUCTING MAGNET SYSTEMS (4 pages)
- 4Q06250PS-430 Integrated Power Supply System (216 pages)
- 4Q12125PS-430 Integrated Power Supply System (216 pages)
- 430 Power Supply Programmer (4 pages)
- 110 Liquid Helium Level Meter (CE-Marked) (30 pages)
- 420 Power Supply Programmer (134 pages)
- 175 Industrial Level Transmitter (CE-Marked) (18 pages)
- 05100PS-430-601 High Stability Integrated Power Supply System (226 pages)
- 4Q12125PS-430 High Stability Integrated Power Supply System (216 pages)
- 4Q06125PS-430 High Stability Integrated Power Supply System (216 pages)
- 160 Liquid Helium Level Superconducting Dipstick (4 pages)
- 05200PS-430-601 Integrated Power Supply System (224 pages)
- 4Q1010PS-430 Integrated Power Supply System (214 pages)
- 05300PS-430-601 High Stability Integrated Power Supply System (226 pages)
- 4Q06250PS-430 High Stability Integrated Power Supply System (216 pages)
- 185 & 186 Liquid Level Instruments (CE-Marked) (82 pages)
- 03300PS-430-601 High Stability Integrated Power Supply System (226 pages)
- 135 & 136 Liquid Helium Level Instruments (CE-Marked) (72 pages)