beautypg.com

Foreword – American Magnetics 4Q1005PS-430 Integrated Power Supply System User Manual

Page 15

background image

Rev.

5

xv

Foreword

General Precautions

In the event a person is burned by a cryogen or material cooled to

cryogenic temperatures, the following first aid treatment should be given

pending the arrival and treatment of a physician or other medical care

worker:

1. If any cryogenic liquid contacts the skin or eyes, immediately flush

the affected area gently with tepid water (102°F − 105°F, 38.9°C −

40.5°C) and then apply cold compresses.

2. Do not apply heat. Loosen any clothing that may restrict

circulation. Apply a sterile protective dressing to the affected area.

3. If the skin is blistered or there is any chance that the eyes have

been affected, get the patient immediately to a physician for

treatment.

Containers of cryogenic liquids are self pressurizing (as the liquid boils off,

vapor pressure increases). Hoses or lines used to transfer these liquids

should never be sealed at both ends (i.e. by closing valves at both ends).

When pouring cryogenic liquids from one container to another, the

receiving container should be cooled gradually to prevent damage by

thermal shock. The liquid should be poured slowly to avoid spattering due

to rapid boil off. The receiving vessel should be vented during the transfer.

Introduction of a substance at or near room temperature into a cryogenic

liquid should be done with great caution. There may be a violent gas boil-

off and a considerable amount of splashing as a result of this rapid boiling.

There is also a chance that the material may crack or catastrophically fail

due to forces caused by large differences in thermal contraction of different

regions of the material. Personnel engaged in this type of activity should

be instructed concerning this hazard and should always wear a full face

shield and protective clothing. If severe spraying or splashing could occur,

safety glasses or chemical goggles along with body length protective

aprons will provide additional protection.

The properties of many materials at extremely low temperatures may be

quite different from the properties that these same materials exhibit at

room temperatures. Exercise extreme care when handling materials cooled

to cryogenic temperatures until the properties of these materials under

these conditions are known.

Metals to be used for use in cryogenic equipment application must posses

sufficient physical properties at these low temperatures. Since ordinary

carbon steels, and to somewhat a lesser extent, alloy steels, lose much of

their ductility at low temperatures, they are considered unsatisfactory and

sometimes unsafe for these applications. The austenitic Ni-Cr alloys

exhibit good ductility at these low temperatures and the most widely used