Remote programming and monitoring, Environmental specification, Mechanical specification – American Magnetics 12200PS DC Power Supply (CE-Marked) User Manual
Page 14

OPERATING MANUAL
FEATURES AND SPECIFICATIONS
Release 1.0 (98/07)
1-5
1.3.5
Remote Programming and Monitoring
Remote Analog Programming (Full Scale Input)
Voltage and current programming:
0-5k, 0-10k resistances; 0-5V, 0-10V voltage sources
Remote Monitoring
Output voltage and current: 0-5V, 0-10V
0 to full scale output 1% accuracy.
Maximum Remote Sense Line Drop Compensation
5V/line (Line drop is subtracted from total voltage
available at supply output.)
Remote Start/Stop and Interlock
2.5-15V signal or TTL-compatible input, selectable logic
Optional Isolated Program and Readback (V&I)
0-5V (ISOL Interface)
Optional Digital Control
RS-232, GPIB Interfaces
1.3.6 Environmental
Specification
Operating Temperature Range
0°C to 50°C
Storage Temperature Range
-20°C to +70°C
Humidity Range
30% to 90% RH Non-condensing
Operating Altitude
Derate maximum operating temperature by 1°C per 1,000
feet (300 m) for operation between 5,000 feet (1500 m)
and 15,000 feet (4500 m).
Storage Altitude
Up to 50,000 feet (15 000 m).
Installation Category
Intended for use in installation category (overvoltage
category) II (IEC 1010-1 standard).
1.3.7
Mechanical Specification
Front Panel Control
10-turn voltage and current potentiometers
Front Panel Voltage Control Resolution
0.02% of V max
Meter Accuracy
See Table 1.3-1 and Table 1.3-2
AC Input Connector Type
3-terminal, 34A, 250V, right angle, PC mount,
wire clamp connector with strain relief cover
Output
7.5V to 100V models: nickel-plated copper bus bars with
bus bar cover and strain relief; bus bar holes: 0.343"
(8.7 mm) D (1), 0.197" (5.0 mm) D (2);
150V to 600V models: 4-terminal, right angle, PC mount,
wire clamp connector
Sense Connector
5-terminal wire clamp connector (2 piece)
Analog Programming Connector
15-terminal wire clamp connector (2 piece)
Chassis Ground
One chassis ground screw located on rear panel for
bonding connections
Cooling
Fan cooled. Air exhausts to rear. Over temperature
shutdown: automatic restart or latch off.
Mounting
Removable rack mount brackets. Mount at front panel or
mid-chassis location.
Weight
Approximately 33 lbs. (15 kg)
Approvals
CE-marked units meet IEC 1010-1 safety standard and
EN50081-2 and EN50082-1 EMC standards. Additional
standards: CSA C22.2 No. 1010.1, UL 3101, and FCC,
part 15, class A EMI standard.