D table 1.3-2 – American Magnetics 12200PS DC Power Supply (CE-Marked) User Manual
Page 12
OPERATING MANUAL
FEATURES AND SPECIFICATIONS
Release 1.0 (98/07)
1-3
1.3.1
Electrical Specifications (continued)
Table 1.3-2 Specifications for 100V to 600V Models
Models
100-28
150-18
300-9
600-4
Output Ratings:
Output Voltage
Output Current
Output Power
0-100V
0-28A
2800W
0-150V
0-18A
2700W
0-300V
0-9A
2700W
0-600V
0-4A
2400W
Line Regulation:
Voltage
(0.01% of Vmax + 2mV)
Current (0.01% of Imax + 2mA)
12mV
4.8mA
17mV
3.8mA
32mV
2.9mA
62mV
2.4mA
Load Regulation:
Voltage (0.02% of Vmax + 5mV)
Current (0.02% of Imax + 5mA)
27mV
10.6mA
35mV
8.6mA
65mV
6.8mA
125mV
5.8mA
Meter Accuracy:
Voltage (1% of Vmax + 1 count)
Current (1% of Imax + 1 count)
1.1V
0.38A
1.6V
0.19A
4V
0.1A
7V
0.05A
Output Noise (0-20MHz): Voltage (p-p)
175mV
200mV
400mV
500mV
Output Ripple (rms): Voltage
Current
25mV
80mA
25mV
40mA
40mV
20mA
100mV
10mA
Drift (30 minutes):
Voltage (0.05% of Vmax)
Current (0.6% of Vmax)
For Resistive Programming:
Voltage (0.6% of Vmax)
Current (0.6% of Imax)
50mV
168mA
600mV
168mA
75mV
108mA
900mV
108mA
150mV
54mA
1800mV
54mA
300mV
24mA
3600mV
24mA
Voltage (0.05% of Vmax)
Current (0.05% of Imax)
For Resistive Programming:
Voltage (0.3% of Vmax)
Current (0.3% of Imax)
50mV
14mA
300mV
84mA
75mV
9mA
450mV
54mA
150mV
4.5mA
900mV
27mA
300mV
2mA
1800mV
12mA
Temperature Coefficient:
Voltage (0.02% of Vmax/°C)
Current (0.03% of Imax/°C)
For Resistive Programming:
Voltage (0.06% of Vmax/°C)
Current (0.06% of Imax/°C)
20mV
8.4mA
60mV
16.8mA
30mV
5.4mA
90mV
10.8mA
60mV
2.7mA
180mV
5.4mA
120mV
1.2mA
360mV
2.4mA
OVP Adjustment Range:
(5% to 110% of Vmax)
5-110V
7.5-165V
15-330V
30-660V
0.90
0.90
0.91
0.91
1
Minimum output voltage is <0.15% of rated voltage at zero output setting.
2 For input voltage variation over the AC input voltage range, with constant rated load.
3 For 0-100% load variation, with constant nominal line voltage.
4 Current mode noise is measured from 10% to 100% of rated output voltage, full current.
5 Maximum drift over 30 minutes with constant line, load, and temperature, after power on.
6 Maximum drift over 8 hours with constant line, load, and temperature, after 30-minute warm-up.
7
Change in output per
°
C change in ambient temperature, with constant line and load.
8
Typical efficiency at nominal input voltage and full output power.