beautypg.com

D table 1.3-2 – American Magnetics 12200PS DC Power Supply (CE-Marked) User Manual

Page 12

background image

OPERATING MANUAL

FEATURES AND SPECIFICATIONS

Release 1.0 (98/07)

1-3

1.3.1

Electrical Specifications (continued)

Table 1.3-2 Specifications for 100V to 600V Models

Models

100-28

150-18

300-9

600-4

Output Ratings:

Output Voltage

1

Output Current
Output Power

0-100V
0-28A
2800W

0-150V
0-18A
2700W

0-300V
0-9A
2700W

0-600V
0-4A
2400W

Line Regulation:

2

Voltage

(0.01% of Vmax + 2mV)

Current (0.01% of Imax + 2mA)

12mV
4.8mA

17mV
3.8mA

32mV
2.9mA

62mV
2.4mA

Load Regulation:

3

Voltage (0.02% of Vmax + 5mV)
Current (0.02% of Imax + 5mA)

27mV
10.6mA

35mV
8.6mA

65mV
6.8mA

125mV
5.8mA

Meter Accuracy:

Voltage (1% of Vmax + 1 count)
Current (1% of Imax + 1 count)

1.1V
0.38A

1.6V
0.19A

4V
0.1A

7V
0.05A

Output Noise (0-20MHz): Voltage (p-p)

175mV

200mV

400mV

500mV

Output Ripple (rms): Voltage

Current

4

25mV
80mA

25mV
40mA

40mV
20mA

100mV
10mA

Drift (30 minutes):

5

Voltage (0.05% of Vmax)
Current (0.6% of Vmax)

For Resistive Programming:

Voltage (0.6% of Vmax)
Current (0.6% of Imax)

50mV
168mA

600mV
168mA

75mV
108mA

900mV
108mA

150mV
54mA

1800mV
54mA

300mV
24mA

3600mV
24mA

Drift (8 hours):

6

Voltage (0.05% of Vmax)
Current (0.05% of Imax)

For Resistive Programming:

Voltage (0.3% of Vmax)
Current (0.3% of Imax)

50mV
14mA

300mV
84mA

75mV
9mA

450mV
54mA

150mV
4.5mA

900mV
27mA

300mV
2mA

1800mV
12mA

Temperature Coefficient:

7

Voltage (0.02% of Vmax/°C)
Current (0.03% of Imax/°C)

For Resistive Programming:

Voltage (0.06% of Vmax/°C)
Current (0.06% of Imax/°C)

20mV
8.4mA

60mV
16.8mA

30mV
5.4mA

90mV
10.8mA

60mV
2.7mA

180mV
5.4mA

120mV
1.2mA

360mV
2.4mA

OVP Adjustment Range:

(5% to 110% of Vmax)

5-110V

7.5-165V

15-330V

30-660V

Efficiency:

8

0.90

0.90

0.91

0.91

1

Minimum output voltage is <0.15% of rated voltage at zero output setting.

2 For input voltage variation over the AC input voltage range, with constant rated load.
3 For 0-100% load variation, with constant nominal line voltage.
4 Current mode noise is measured from 10% to 100% of rated output voltage, full current.
5 Maximum drift over 30 minutes with constant line, load, and temperature, after power on.
6 Maximum drift over 8 hours with constant line, load, and temperature, after 30-minute warm-up.
7

Change in output per

°

C change in ambient temperature, with constant line and load.

8

Typical efficiency at nominal input voltage and full output power.