Additional Specifications
Rise Time (No Load, Full Load):
7.5V to 60V models: 100 ms; 100V to 600V models: 170 ms
Fall Time (No Load):
4 s
Fall Time (Full Load):
7.5V to 60V models: 100 ms; 100V to 600V models: 170 ms
Voltage Mode Transient Response:
<3 ms
Time Delay from power on until output stable
7 seconds maximum
1.3.3 Input
Conditions
AC Input Voltage Ranges
190-264Vac, 1
φ
(24.3A maximum at 208Vac; 22.4A
maximum at 230Vac)
Source Frequency
47-63Hz
Power Factor
0.65 typical
Figure 1.3-1 Typical Input Current Characteristics
(Based on 100V, 28A model.)
1.3.4
Additional Characteristics
Switching Frequency
Nominal 31kHz (62kHz output ripple)
Output Hold-up Time
Greater than 10 ms with interruption of AC line, for
nominal AC input and full load
Maximum Voltage Differential
from either output to safety ground
600Vdc
1 Measured with stepped 0-10V analog programming source and a resistive load.
2 Measured with stepped 0-10V analog programming source and a resistive load.
3 Measured with stepped 0-10V analog programming source and a resistive load.
4 Time for the output voltage to recover within 0.5% of its previous level after a step change in load current of 10% to 90% of
rated output. Load slew rate <6A/
µ
s.
I
N
P
U
T
C
U
R
R
E
N
T
(A)
OUTPUT VOLTAGE
25
20
15
10
5
50%
100%
50% at 190Vac
100% at 264Vac
0
O
U
T
P
U
T
C
U
R
R
E
N
T
100% at 190Vac
50% at 264Vac
30