Calibration for Vertical Surfaces (see figure F)
The surface onto which you place the measuring tool must not deviate from
the vertical line by more than 5°. If the deviation is greater, the calibration
process is discontinued with the indication “---”.
Switch the measuring tool on and position it on the vertical surface in
such a manner that the spirit level 13 faces upward and the display 11
faces you. Wait for 10 s.
Then press the calibration button “CAL” 4 for approx. 2 s until “CAL1”
briefly appears in the display. Afterwards, the measuring value flashes
in the display.
Turn the measuring tool by 180° around the vertical axis so that the
spirit level still faces upward, but the display 11 faces away from you.
Wait for 10 s.
Then press the calibration button “CAL” 4 again. “CAL2” is briefly in-
dicated in the display. Afterwards, the measuring value appears in the
display (no longer flashing). The measuring tool is now re-calibrated
for this supporting surface.
After this, the measuring tool must be calibrated for the opposite sup-
porting surface. Rotate the measuring tool around the horizontal axis
in such a manner that the spirit level 13 faces downward and the dis-
play 11 faces you. Place the measuring tool against the vertical sur-
face. Wait for 10 s.
Then press the calibration button “CAL” 4 for approx. 2 s until “CAL1”
briefly appears in the display. Afterwards, the measuring value flashes
in the display.
Turn the measuring tool 180° around the vertical axis so that the spirit
level still faces downward but the display 11 is facing away from you.
Wait for 10 s.
Then press the calibration button “CAL” 4 again. “CAL2” is briefly in-
dicated in the display. Afterwards, the measuring value appears in the
display (no longer flashing). The measuring tool is now re-calibrated
for both vertical supporting surfaces.
Note: If the measuring tool is not turned around the axis shown in the figure
in steps and , then the calibration cannot be completed (“CAL2” is
not indicated in the display).
Maintenance and Service
Maintenance and Cleaning
Store and transport the measuring tool only in the supplied protective pouch.
Keep the measuring tool clean at all times.
Do not immerse the measuring tool in water or other fluids.
Wipe off debris using a moist and soft cloth. Do not use any cleaning agents
or solvents.
Regularly clean the surfaces at the exit opening of the laser in particular,
and pay attention to any fluff of fibres.
If the measuring tool should fail despite the care taken in manufacturing and
testing procedures, repair should be carried out by an authorised after-sales
service centre for Bosch power tools. Do not open the measuring tool your-
self.
In all correspondence and spare parts orders, please always include the
10-digit article number given on the type plate of the measuring tool.
In case of repairs, send in the measuring tool packed in its protective
pouch 24.
After-sales Service and Customer Assistance
Our after-sales service responds to your questions concerning mainte-
nance and repair of your product as well as spare parts. Exploded views and
information on spare parts can also be found under:
www.bosch-pt.com
Our customer service representatives can answer your questions concern-
ing possible applications and adjustment of products and accessories.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham
Uxbridge
UB 9 5HJ
Tel. Service: +44 (0844) 736 0109
Fax: +44 (0844) 736 0146
E-Mail: [email protected]
Ireland
Origo Ltd.
Unit 23 Magna Drive
Magna Business Park
City West
Dublin 24
Tel. Service: +353 (01) 4 66 67 00
Fax: +353 (01) 4 66 68 88
OBJ_BUCH-1628-002.book Page 19 Monday, August 27, 2012 12:22 PM