Battery pack installation, A. battery reinstallation, Figure 25. battery pack installation – ACR&Artex ME406 Portable ELT User Manual
Page 71: Subtask 25-62-31
25-62-31
Page 71 of 85
JUN 25/13
ARTEX PRODUCTS / ACR ELECTRONICS, INC
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
ME406P (453-6611)
TASK 25-62-31-450-806
8. Battery Pack Installation
SUBTASK 25-62-31-450-001
A. Battery Reinstallation
CAUTION:
THE BATTERY PACK CONTAINS ELECTROSTATIC DISCHARGE SENSITIVE (ESD)
COMPONENTS AND IT MUST BE HANDLED WITH CARE. IF POSSIBLE, WEAR A
GROUNDED WRIST STRAP WHEN HANDLING THE BATTERY PACK DURING
INSTALLATION ACTIVITIES. TAKE PARTICULAR CARE TO AVOID TOUCHING THE
EXPOSED CIRCUIT BOARD AND CONNECTOR PINS ON THE BOARD.
(1)
This subtask applies to reinstallation of an existing battery that was removed for inspection
and testing.
(2)
See Figure 24. Velcro Strap Installation & Inspection.
Figure 25. Battery Pack Installation
(3)
Verify the gasket is in place and in good condition.
(4)
Lay the battery pack on the work surface with the cells facing up.
(5)
Align the ELT with the battery pack, holding it slightly above the pack with one hand.
(6)
Connect the ELT flex cable receptacle to the plug on the battery pack circuit board using the
other hand, taking care not to put a twist in the flex cable.
NOTE: The receptacle should “click” into place when properly mated to the plug.
SCREW P/N 201-0402
(8 PLCS)
GASKET
ELT ASSEMBLY
BATTERY PACK
CONNECT
(ELT flex cable not
shown for clarity)