Elt installation, A. installation and test, Figure 23. elt installation sequence – ACR&Artex ME406 Portable ELT User Manual
Page 68
ARTEX PRODUCTS / ACR ELECTRONICS, INC
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
ME406P (453-6611)
25-62-31
Page 68 of 85
JUN 25/13
TASK 25-62-31-410-802
7. ELT Installation
SUBTASK 25-62-31-410-001
A. Installation and Test
CAUTION:
TAKE CARE TO KEEP THE REMOTE SWITCH PLUG STRAIGHT WHEN CONNECTING IT
TO THE ELT. IF THE PLUG IS COCKED (I.E., CROOKED) WHEN INSERTING IT INTO
THE ELT RECEPTACLE, THE ELT MAY ACTIVATE. IF THE ELT ACTIVATES, RESET IT BY
CYCLING THE LOCAL CONTROL SWITCH TO “ON” AND THEN BACK TO “ARM”.
(1)
See Figure 23. ELT Installation Sequence.
Figure 23. ELT Installation Sequence
(2)
Verify the ELT local switch is in the “ARM” position.
(3)
Insert the ELT into the mounting tray at an angle, such that the locking ears at the end
opposite the direction-of-flight arrow fit into the mounting tray locking slots.
(4)
Press the ELT down until it is fully seated in the mounting tray.
MOUNTING
TRAY ASSY
ELT MAIN
ASSEMBLY
4
3
2
1
CONNECT COAX
CONNECT HARNESS
CLOSE VELCRO STRAP
(STRAP SHOWN IN
CLOSED POSITION)
NOTE: Coax cable and
wiring harness not
shown for clarity.
MOUNTING
TRAY ASSY
ELT MAIN
ASSEMBLY
4
3
2
1
CONNECT COAX
CONNECT HARNESS
CLOSE METAL STRAP
(STRAP SHOWN IN
CLOSED POSITION)
NOTE: Coax cable and
wiring harness not
shown for clarity.