beautypg.com

C. elt d-sub plug installation – ACR&Artex ME406 Portable ELT User Manual

Page 63

background image

25-62-31

Page 63 of 85

JUN 25/13

ARTEX PRODUCTS / ACR ELECTRONICS, INC

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

ME406P (453-6611)

(7)

Prepare the wires fabricated in Step (6), as described in Steps (2)(a) and (2)(b).

(8)

Crimp appropriately sized ring terminals on the buzzer ends of the buzzer power and ground

wires.

(9)

Crimp an appropriately sized ring terminals on the airframe end of the ground wires.

(10) Crimp an appropriately sized ring terminal on the remote switch power source wire end.

NOTE: If desired, the power wire may be spliced to an unswitched power source in a

manner acceptable to the aircraft manufacturer, or as described in AC 43.13-1,

Paragraph 11-167.

(11) Crimp female terminal pins (151-6628) to the cockpit remote switch end, as follows:

NOTE: Use Molex crimp tool 63811-3300, or an equivalent tool for 0.062 in. terminal pins.

(a)

Each harness wire.

(b)

Remote switch ground wire.

(c)

Remote switch power wire.

(12) Bundle the wiring into a complete harness, with breakouts as appropriate, such that the wiring

can be properly supported and attached to the airframe. Refer to the aircraft manufacturer’s

written instructions or AC 43.13-1, Chapter 11, § 9 through 12, as applicable.

SUBTASK 25-62-31-450-002

C. ELT D-Sub Plug Installation

NOTE: Artex supplies a DB15 female soler contact connector with all ME406 ELT kits. If a crimp contact

connector is preferred, it is acceptable to purchase and use an alternate DB15 crimp contact

connector. Ensure it conforms to MIL-C-24308 or other commercial specification to ensure

performance requirements are met.

NOTE: If moisture intrusion is a possibility, seal the back side of the connector. See SUBTASK 25-62-31-

450-001 on page 62.

(1)

Select a rubber grommet, supplied as part of the D-Sub housing kit (150-1127), that fits

snugly around the harness wiring.

(2)

Feed the wiring harness, ground wire, and buzzer power wire through the rubber grommet,

such that the raised collar end of the grommet fits inside the housing. See Figure 22. D-Sub

Plug Assembly on page 65.

NOTE: For composite airframe installations, the buzzer ground wire should also be routed

through the grommet.