Specifications, A. environmental and physical, Table 2. environmental and physical specifications – ACR&Artex ME406 Portable ELT User Manual
Page 29
25-62-31
Page 29 of 85
JUN 25/13
ARTEX PRODUCTS / ACR ELECTRONICS, INC
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
ME406P (453-6611)
TASK 25-62-31-870-803
3. Specifications
SUBTASK 25-62-31-870-001
A. Environmental and Physical
(1)
Table 2 lists the environmental and physical specifications of the ME406P ELT.
NOTE: For automatic activation, the higher threshold of 4.5 ft/sec (2.3
g
) is specified in
accordance with Eurocae ED-62. Use of the higher threshold crash sensor has been
approved by the FAA as a deviation to TSO C126 (FAA Reference #98-130S-108,
February 6, 1998).
Table 2. Environmental and Physical Specifications
CRITERIA
PARAMETER
CHARACTERISTIC
Temperature
Storage
-55° C to +85° C
Operating
-20° C to +55° C
Mechanical
Vibration
10
g
, 5 Hz to 2,000 Hz
Shock
500
g
for 4 ms
Crashworthiness
100
g
for 23 ms
Humidity
95% for 50 hours
Penetration
55 lbs from 6 in. (25 kg from 15 cm)
Crush
1,000 lbs (454 kg)
Altitude
55,000 ft (16,764 m)
Automatic Activation
Primary G-Switch
4.5 ±0.5 ft/sec (2.3
g
)
Auxiliary Five G-Switches
12
g
Weight
ELT Complete w/Battery Pack, and
Mounting Tray
1.95 lbs (0.8 kg)
Dimensions (L x W x H)
ELT Complete w/Battery Pack, and
Mounting Tray
6.60 x 3.69 x 2.86 in.
(168 x 94 x 73 mm)
Software
In accordance with RTCA/DO-178B, Level D