Figure 19. metal airframe wiring diagrams – ACR&Artex ME406 Portable ELT User Manual
Page 60
ARTEX PRODUCTS / ACR ELECTRONICS, INC
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
ME406P (453-6611)
25-62-31
Page 60 of 85
JUN 25/13
Figure 19. Metal Airframe Wiring Diagrams
ELT D-SUB
PLUG
CABLE
SHIELD
REMOTE SWITCH
MOLEX PLUG
SHIELD USED AS GROUND WIRE
LIGHT
RESET 1
RESET 2
EXTERNAL ON
G-SWITCH LOOP
G-SWITCH LOOP
GROUND
AUDIO POWER
2
6
13
14
5
12
7
8
8
5
2
7
1
3
6
9
+14V
OR
+28v
UNSWITCHED
POWER
1/2A SLO-BLO FUSE
NOTE: PINS 6 & 9 OF REMOTE
SWITCH ARE INTERNALLY
TIED WITHIN THE REMOTE
SWITCH ASSEMBLY.
NOTE: N/C PINS 1, 3, 4,
9, 10, 11, 15.
RED +
BLK –
AUDIO
INDICATOR
452-6505
METAL AIRFRAME WITH SHIELDED CABLE
ELT D-SUB
PLUG
REMOTE SWITCH
MOLEX PLUG
LIGHT
RESET 1
RESET 2
EXTERNAL ON
G-SWITCH LOOP
G-SWITCH LOOP
GROUND
AUDIO POWER
2
6
13
14
5
12
7
8
8
5
2
7
1
3
6
9
+14V
OR
+28v
UNSWITCHED
POWER
1/2A SLO-BLO FUSE
NOTE: PINS 6 & 9 OF REMOTE
SWITCH ARE INTERNALLY
TIED WITHIN THE REMOTE
SWITCH ASSEMBLY.
NOTE: N/C PINS 1, 3, 4,
9, 10, 11, 15.
RED +
BLK –
AUDIO
INDICATOR
452-6505
METAL AIRFRAME WITH UNSHIELDED CABLE
AIRFRAME
GROUND (TYP.)
AIRFRAME
GROUND (TYP.)
PIN INSERTION END OF MOLEX
PLUG FOR REMOTE SWITCH
ASSEMBLY. HOLE NUMBERING
IS IDENTICAL TO THAT INSCRIBED
ON ACTUAL PLUG. ORIENTATION
SHOWN IS SAME AS INSERTION
ORIENTATION FOR INSTALLED
SWITCH.
9
8
7
6
5
4
3
2
1
SOLDER CUP (BACK) SIDE OF D-SUB PLUG
FOR ELT. HOLE NUMBERING IS IDENTICAL
TO THAT INSCRIBED ON ACTUAL PLUG.
1
9
8
15