3. Fault Isolation

SUBTASK 25-62-31-810-001

A. Self-Test Error Troubleshooting Guidelines

(1)

Table 6 describes the ELT self-test LED error codes (i.e., flash codes), their probable causes,

and possible solutions. The 5-flash error is not present when the ELT is programmed with a

serial user protocol (short message).

NOTE: Upon activation, the LED will display a long single flash, which is normal. Any self-

test error codes will display following this initial flash. If there are multiple errors,

there is a 0.5 to 1.0 second pause between each error code.

Table 6. ELT Self-Test Error Codes Troubleshooting Guide

CODE

PROBABLE CAUSE

POSSIBLE SOLUTION

3-Flash

Indicates a 406 MHz transmission problem

Open or short condition on antenna

output or coax cable

Verify the coax cable/antenna is

connected and in good condition

Perform continuity check of center

conductor and shield

Check for a shorted cable

Check for intermittent connection in the

coax cable

Antenna or installation faulty

Check with a VSWR meter. Check antenna

for opens, shorts, or a resistive ground

plane connection

Impedance presented by antenna

Lengthen or shorten antenna coax cable

length by 4 to 6 inches

Insufficient ground plane

Provide ground plane at least 12 inches in

diameter

Upright metal structure obstructing

antenna causing re-radiation

Stay at least 10-12 inches away from

upright metal structures

Low power output

Battery low

3A fuse on battery pack circuit board

faulty

ELT local ground not connected

Verify continuity between antenna ground

plane and ELT local ground connection.

Transmitter module faulty

Cannot be repaired in field - Return to

factory for servicing