B. electrical, Table 3. electrical specifications – ACR&Artex ME406 Portable ELT User Manual
Page 30
ARTEX PRODUCTS / ACR ELECTRONICS, INC
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
ME406P (453-6611)
25-62-31
Page 30 of 85
JUN 25/13
SUBTASK 25-62-31-870-002
B. Electrical
(1)
Table 3 lists the electrical specifications of the ME406P ELT.
Table 3. Electrical Specifications
CRITERIA
PARAMETER
CHARACTERISTIC
Operating Frequencies
406.028 MHz, or higher
± 1 KHz
121.5 MHz
± 6.075 kHz
Modulation
406 MHz
Bi-Phase L (G1D)
121.5 MHz
Amplitude Modulation (A3X)
Transmitter Duty Cycle
406 MHz
440 ms (± 1%), or
520 ms (± 1%), every
50 seconds (± 5%)
121.5 MHz
Continuous
Peak Effective Radiated
Power (PERP)
406 MHz
3.2 W to 7.2 W (37 dBm ± 2 dBm)
PERP or EIRP for 24 hrs
@ -20° C to +55° C
121.5 MHz
Min. 50 mW (17 dBm) PERP for 50 hrs
@ -20° C to +55° C
or 100 mW EIRP (20 dBm) for 48 hrs
@ -20° C to +55° C
Occupied Bandwidth
406 MHz
20 KHz max.
121.5 MHz
25 KHz max.
Spurious Emissions
406 MHz
Per RTCA/DO-204
121.5 MHz
Per CFR Title 47 (FCC), Part 87
Battery
Type of Cell
Lithium Manganese Dioxide
Voltage
6.0
Amp-Hour Rating
11.1