beautypg.com

B. electrical, Table 3. electrical specifications – ACR&Artex ME406 Portable ELT User Manual

Page 30

background image

ARTEX PRODUCTS / ACR ELECTRONICS, INC

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

ME406P (453-6611)

25-62-31

Page 30 of 85

JUN 25/13

SUBTASK 25-62-31-870-002

B. Electrical

(1)

Table 3 lists the electrical specifications of the ME406P ELT.

Table 3. Electrical Specifications

CRITERIA

PARAMETER

CHARACTERISTIC

Operating Frequencies

406.028 MHz, or higher

± 1 KHz

121.5 MHz

± 6.075 kHz

Modulation

406 MHz

Bi-Phase L (G1D)

121.5 MHz

Amplitude Modulation (A3X)

Transmitter Duty Cycle

406 MHz

440 ms (± 1%), or

520 ms (± 1%), every

50 seconds (± 5%)

121.5 MHz

Continuous

Peak Effective Radiated

Power (PERP)

406 MHz

3.2 W to 7.2 W (37 dBm ± 2 dBm)

PERP or EIRP for 24 hrs

@ -20° C to +55° C

121.5 MHz

Min. 50 mW (17 dBm) PERP for 50 hrs

@ -20° C to +55° C

or 100 mW EIRP (20 dBm) for 48 hrs

@ -20° C to +55° C

Occupied Bandwidth

406 MHz

20 KHz max.

121.5 MHz

25 KHz max.

Spurious Emissions

406 MHz

Per RTCA/DO-204

121.5 MHz

Per CFR Title 47 (FCC), Part 87

Battery

Type of Cell

Lithium Manganese Dioxide

Voltage

6.0

Amp-Hour Rating

11.1