beautypg.com

Wiring, A. general considerations and recommendations – ACR&Artex ME406 Portable ELT User Manual

Page 59

background image

25-62-31

Page 59 of 85

JUN 25/13

ARTEX PRODUCTS / ACR ELECTRONICS, INC

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

ME406P (453-6611)

TASK 25-62-31-450-805

6. Wiring

SUBTASK 25-62-31-990-001

A. General Considerations and Recommendations

CAUTION:

IF GROUND OR OTHER CONNECTIONS ARE BROKEN OR OTHERWISE DAMAGED, THE

ELT IS STILL CAPABLE OF AUTOMATIC ACTIVATION; HOWEVER, THE COCKPIT

REMOTE SWITCH MAY BE INCAPABLE OF RESETTING THE ELT AND OPERATION MAY

NOT BE INDICATED ON THE REMOTE SWITCH LED.

CAUTION:

INCORRECT TERMINATION OF THE WIRING IN THE CONNECTORS MAY DAMAGE THE

ELT, CAUSE TRANSMISSION ISSUES, OR RESULT IN A NON-FUNCTIONING REMOTE

SWITCH. VERIFY THE WIRING AGAINST THE WIRING DIAGRAM AND PERFORM A

CONTINUITY CHECK TO CONFIRM GOOD CONNECTIONS AND PROPER PIN

LOCATIONS.

CAUTION:

TO PREVENT INADVERTENT ELT ACTIVATION OR POSSIBLE COMPONENT DAMAGE,

DO NOT CONNECT THE HARNESS TO THE ELT OR COCKPIT REMOTE SWITCH UNTIL

ALL POWER AND GROUND WIRING CONNECTIONS ARE COMPLETED.

(1)

The following wiring and grounding considerations and recommendations are applicable:

(a)

Minimum 22 AWG wire size.

(b)

Shielding is recommended to help prevent EMI and RF interference.

(c)

Use high quality conductor meeting MIL-W-16878, M22759, M27500, or a commercial

equivalent acceptable for use in aircraft applications.

(d)

Provide a “Drip Loop” in the remote switch harness connection to the ELT to divert

moisture from the connector. See TASK 25-62-31-990-805 on page 17 for a definition.

(e)

Provide a “Service Loop” in the remote switch harness connection to the remote switch

assembly, such that the assembly can be withdrawn from the panel far enough to easily

disconnect the harness plug. See TASK 25-62-31-990-805 on page 17 for a definition.

(f)

ELT and remote switch grounds must be common to aircraft ground and should be less

than 10Ω.

(2)

See Figure 19. Metal Airframe Wiring Diagrams on page 60 and Figure 20. Composite Airframe

Wiring Diagrams on page 61. Choose the appropriate wiring diagram, depending upon the

following factors:

(a)

Metal or composite airframe, and

(b)

A shielded or unshielded remote switch harness cable is chosen for the installation.