I. airframe ground connections, J. buzzer connections, K. remote switch final installation – ACR&Artex C406-2 HM User Manual
Page 69: 70 j. buzzer connections, Subtask
![background image](/manuals/248013/69/background.png)
25-62-11
Page 69 of 87
JUN 20/13
ACR ELECTRONICS, INC / ARTEX PRODUCTS
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
C406-2 (453-5000), C406-2HM (453-5001)
SUBTASK 25-62-11-450-008
I.
Airframe Ground Connections
(1)
Connect the ground wires to the airframe in accordance with the aircraft manufacturer’s
written instructions or as described in AC 43.13-1, Chapter 11, § 15, as applicable. See "Figure
21 Remote Switch Harness Wiring Diagram” on page 66.
SUBTASK 25-62-11-450-009
J.
Buzzer Connections
(1)
Connect the power wire to the buzzer positive (+) terminal.
(2)
Connect the ground wire to the buzzer negative (–) terminal.
SUBTASK 25-62-11-450-010
K. Remote Switch Final Installation
(1)
Insert the harness plug into the remote switch receptacle.
(2)
Install the remote switch assembly in accordance with SUBTASK 25-62-11-450-002 on page