MEASURING DEVICE TO PROTECT THE INPUT CIRCUITS OF THE MEASURING DEVICE.
(1)
Connect the measuring device, referring to SUBTASK 25-62-11-750-002 on page 40.
(2)
Activate the ELT, if necessary, by placing the control switch in the “ON” position.
(3)
Wait three minutes.
(4)
Read the displayed amplitude of the 406 MHz burst that follows the three-minute wait period.
The amplitude must be within the minium specified for 406 MHz in Table 3 on page 34, at the
output terminal.
(5)
Deactivate the ELT by placing the control switch in the “OFF” position.