beautypg.com

B. elt troubleshooting guidelines, Table 7 elt troubleshooting guide – ACR&Artex C406-2 HM User Manual

Page 49

background image

25-62-11

Page 49 of 87

JUN 20/13

ACR ELECTRONICS, INC / ARTEX PRODUCTS

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

C406-2 (453-5000), C406-2HM (453-5001)

SUBTASK 25-62-11-810-002

B. ELT Troubleshooting Guidelines

(1)

Table 7 provides ELT troubleshooting guidelines for installation and operational issues.

Table 7 ELT Troubleshooting Guide

5-Flash

Indicates there is no navigation position data present

Aircraft navigation system off

Turn on navigation system

Faulty system interface wiring or

connections

Check wiring and connections for

continuity and security

No 453-6500 ELT/NAV Interface installed

Install 453-6500 ELT/NAV Interface

Reprogram to short message

7-Flash

Indicates a battery problem

Operating time is >1 hour

Replace battery pack

Electrical circuits faulty

SYMPTOM

PROBABLE CAUSE

POSSIBLE SOLUTION

Remote switch LED always on

(steady)

Improper wiring

Verify wiring

Short circuit

Check for frayed insulation

Verify integrity of all crimp and

solder connections

ELT will not turn off

Battery too low to support 406

burst and causes circuit to reset

Remove battery pack to disable

ELT and replace battery pack

Turn off ELT using local switch - If ELT turns off:

Defective remote switch harness

reset circuit wiring

Check wiring continuity and

repair as necessary

Defective remote switch

Replace remote switch

If ELT does not turn off using local switch:

ELT defective

Remove battery pack to disable

ELT and return ELT to factory for

servicing

CODE

PROBABLE CAUSE

POSSIBLE SOLUTION