Table 6 ELT Self-Test Error Codes Troubleshooting Guide
CODE
PROBABLE CAUSE
POSSIBLE SOLUTION
1-Flash
Indicates a G-switch loop open (Pins 5 and 8)
Remote switch harness connector loose or
disconnected at ELT
Check connector and tighten as necessary
ELT connector pins bent or broken
Check condition of connector pins and
repair or replace as necessary
Connector pins 5 and 8 jumper open
(internal to remote switch harness
connector at ELT end)
Repair open jumper
3-Flash
Indicates a 406 MHz transmission problem
Open or short condition on antenna
output or coax cable
Verify the coax cable/antenna is
connected and in good condition
Perform continuity check of center
conductor and shield
Check for a shorted cable
Check for intermittent connection in the
coax cable
Antenna or installation faulty
Check with a VSWR meter. Check antenna
for opens, shorts, or a resistive ground
plane connection
Impedance presented by antenna
Lengthen or shorten antenna coax cable
length by 4 to 6 inches
Insufficient ground plane
Provide ground plane at least 12 inches in
diameter
Upright metal structure obstructing
antenna causing re-radiation
Stay at least 10-12 inches away from
upright metal structures
Low power output
Battery low
3A fuse on battery pack circuit board
faulty
Improper programming
Verify 406 MHz programming
Transmitter module faulty
Cannot be repaired in field - Return to
factory for servicing