Installation speciðcation, 4 application areas, 5 pressure drop – STIEBEL ELTRON HDB-E Si 01.11.2012 - 31.01.2013 User Manual
Page 27: 6 fault conditions, 7 data table

EN
GL
ISH
www.stiebel-eltron.com
HDB-E Si |
27
INSTALLATION
SpeciÐcation
15.4 Application
areas
Specific electrical resistance and specific electrical conductivity
Standard
specification
at 15 °C
at 20 °C
at 25 °C
Resistance
Ω cm
≥ 1100
≥ 970
≥ 895
Conductivity
mS/m ≤ 91
≤ 103
≤ 112
Conductivity
μs/cm ≤ 910
≤ 1030
≤ 1120
15.5 Pressure
drop
Pressure drop at taps at flow rate of 10 l/min
Mono-lever mixer tap, approx.
MPa
0.04 - 0.08
Thermostatic valve, approx.
MPa
0.03 - 0.05
Hand shower, approx.
MPa
0.03 - 0.15
Sizing the pipework
When calculating the size of the pipework, a pressure drop for the
appliance of 0.1 MPa is recommended.
15.6 Fault
conditions
In case of faults, loads up to a maximum of 95 °C at a pressure of
1.2 MPa can occur temporarily in the installation.
15.7 Data
table
HDB-E 12 Si
HDB-E 18 Si
HDB-E 21 Si
HDB-E 24 Si
232003
232004
232005
232006
Electrical data
Rated output 1
kW
11.0
18
21
24
Rated voltage 1
V
400
400
400
400
Rated current 1
A
16
26
31
35
Fuse 1
A
16
25
32
35
Rated output 2
kW
10.1
16.2
19
21.7
Rated voltage 2
V
380
380
380
380
Rated current 2
A
15.4
24.7
29.5
33.3
Fuse 2
A
16
25
32
35
Rated output 3
kW
11,5
19,4
22,6
25,8
Rated voltage 3
V
415
415
415
415
Rated current 3
A
16
27
32,2
36,3
Fuse 3
A
16
32
32
40
Phases
3/PE
3/PE
3/PE
3/PE
Frequency
Hz
50/-
50/-
50/-
50/-
Max. mains impedance Zmax to DIN EN 61000-3-11
Ohm
0.33
0.33
Conductivity at 15 °C
mS/m
90.9
90.9
90.9
90.9
Specific resistance (≤25 °C)
Ohm cm
1100
1100
1100
1100
Connections
Water connection
G 1/2 A
G 1/2 A
G 1/2 A
G 1/2 A
Application limits
Max. permissible pressure
MPa
1
1
1
1
Values
Max. permissible inlet temperature
°C
25
25
25
25
On
l/min
> 2.3
> 2.3
> 2.3
> 2.3
Flow rate for pressure drop
l/min
3.1
5.2
6.0
6.9
Pressure drop at flow rate
MPa
0.07 (0.02 without
DMB)
0.08 (0.06 without
DMB)
0.10 (0.08 without
DMB)
0.13 (0.1 without
DMB)
Flow rate limit at
l/min
4
7.5
7.5
8.5
DHW delivery
l/min
5.5
9.0
10.5
12