Troubleshooting

199

104-ASR Timer Failure

Audible Beeps: None

Possible Cause: System board failure.

CAUTION: Only authorized technicians trained by HP should

attempt to remove the system board. If you believe the system board
requires replacement, contact HP Technical Support before proceeding.

Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page

80

) and

replace failed components as indicated.

162-System Options Not Set

Audible Beeps: 2 long

Possible Cause: Configuration is incorrect. The system configuration has
changed since the last boot (addition of a hard drive, for example) or a loss of
power to the real-time clock has occurred. The real-time clock loses power if the
onboard battery is not functioning correctly.

Action: Press the F1 key to record the new configuration. Run the server setup
utility to change the configuration. If this message persists, you may need to
replace the onboard battery.

163-Time & Date Not Set

Audible Beeps: 2 long

Possible Cause: Invalid time or date in configuration memory.

Action: Run the server setup utility and correct the time or date.