Drive time-out occurred on physical drive bay x, Drive x indicates position y, Duplicate write memory error – WHP Wireless DL360 User Manual
Page 168: Fyi: drive (bay) x is third-party supplied

168
HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide
Drive Time-Out Occurred on Physical Drive Bay X
Description: ADU issued a command to a physical drive and the command was 
never acknowledged. 
Action: The drive or cable may be bad. Check the other error messages on the 
Diagnostics screen to determine resolution. 
Drive X Indicates Position Y
Description: Message indicates a designated physical drive, which seems to be 
scrambled or in a drive bay other than the one for which it was originally 
configured. 
Action: Examine the graphical drive representation on ADU to determine proper 
drive locations. Remove drive X and place it in drive position Y. Rearrange the 
drives according to the ADU instructions. 
Duplicate Write Memory Error
Description: Data cannot be written to the array accelerator board in duplicate 
due to the detection of parity errors. This is not a data-loss situation. 
Action: Replace the array accelerator board.
Error Occurred Reading RIS Copy from SCSI Port X Drive ID
Description: An error occurred while ADU was trying to read the RIS from this 
drive. 
Action: HP stores the hard drive configuration information in the RIS. If multiple 
errors occur, the drive may need to be replaced. 
FYI: Drive (Bay) X is Third-Party Supplied
Description: Third-party supplied the installed drive.
Action: If problems exist with this drive, replace it with a supported drive.
 
 
 