Troubleshooting

171

Logical Drive X Status = Interim Recovery (Volume Functional, but not Fault
Tolerant)

Description: A physical drive in this logical drive has failed. The logical drive is
operational, but the loss of an additional drive causes permanent data loss.

Action: Replace the failed drive as soon as possible.

Logical Drive X Status = Loose Cable Detected...

...SOLUTION: Turn the system off and attempt to reattach any loose connections. If this
does not work, replace the cable(s) and connection(s).

Description: A physical drive or an external storage unit may have a cabling or
connection problem.

Action: Power the system down and attempt to reconnect any loose connections.
If this does not work, replace the cable(s) and connection(s).

Logical Drive X Status = Overheated

Description: The temperature of the Intelligent Array Expansion System drives
is beyond safe operating levels and has shut down to avoid damage.

Action: Check the fans and the operating environment.

Logical Drive X Status = Overheating

Description: The temperature of the Intelligent Array Expansion System drives
is beyond safe operating levels.

Action: Check the fans and the operating environment.