Wolf Appliance Company SO30F/S User Manual
Page 35

W O L F I N D U C T I O N C O O K T O P S
35
E
6"
(152)
15"
(381)
15"
(381)
2"*
min (51)
CUT-OUT TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
13
3
/
8
"
(340)
COOKTOP CUT-OUT
WIDTH
13
3
/
8
"
(340)
COOKTOP CUT-OUT
WIDTH
33"
(838) RECOMMENDED
CABINET WIDTH
18"
(457)
NOTE: Application shown allows for installation of two 15" (381) modules side-by-side with 33" (838) recommended cabinet width. 18" (457)
recommended cabinet width for installation of single 15" (381) cooktop or module. *Minimum clearance from both side edges of cooktop cut-out
to combustible materials up to 18" (457) above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up
to 18" (457) above countertop.
19
1
/
4
"
(489)
COOKTOP CUT-OUT
DEPTH
2
1
/
2
"
min
(64)
36"
(914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
13"
max
(330)
30"
(762)
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
ABOVE COOKTOP
FRONT OF COUNTERTOP
2
1
/
2
"
min
(64)
19
1
/
4
"
(489)
COOKTOP
CUT-OUT DEPTH
2"**
(51)
21"
(533)
OVERALL
DEPTH
15"
(381)
OVERALL WIDTH
3
1
/
2
"
(89)
O V E R A L L D I M E N S I O N S
Model CT15I/S
I N S T A L L A T I O N S P E C I F I C A T I O N S
Model CT15I/S
Countertop Cut-Out Dimensions
Unit dimensions may vary to ±
1
/
8
" (3).
S P E C I F I C A T I O N S
Model CT15I/S
Trim Finish
Classic
Overall Width
15" (381)
Overall Height
2
1
/
2
" (64)
Overall Depth
21" (533)
Induction Elements
Two
Max Element Power 1800 W
(front)
Max Element Power 2200 W
(rear)
Cabinet Depth
22
3
/
4
" (578) min
Height Clearance
6" (152) min
Cut-Out Width*
13
3
/
8
" (340)
Cut-Out Depth
19
1
/
4
" (489)
Electrical Supply
240/208 V AC, 60 Hz
20 amp circuit
Conduit
4' (1.2 m) flexible 3-wire
Electrical Rating
3.4 kW at 240 V
2.6 kW at 208 V
Shipping Weight
30 lbs (14 kg)
*If the induction cooktop is to be used with
any combination of additional cooktop units or
modules with a filler strip, the cut-out width
increases to 14" (356).
IMPORTANT NOTE: A minimum height clearance of
6" (152) is required. If a shelf is installed
below the unit, a 1" (25) gap at the rear of the
cabinet shelf is necessary to allow for proper
ventilation. Failure to do so could result in
decreased performance or product damage.
Refer to installation
instructions shipped
with each Wolf
product for detailed
specifications.
Discontinued after October 2007