Dimensions in
parentheses are in
millimeters unless
otherwise specified.
12
I N S T A L L A T I O N O P T I O N S
The Wolf E Series single oven may be
installed below a Wolf 30" (762) induction,
electric or gas cooktop. Unless you are using
cabinets deeper than 24" (610), it is recom-
mended that the electrical supply be placed
in the base cabinet to the right of the oven
within reach of the conduit. It may also be
installed below a 36" (914) induction, electric
or gas cooktop.
An E Series single oven may be installed in
combination with a Wolf microwave and
warming drawer. Refer to the warming
drawers section for specifications.
The E Series single oven may be installed
next to another E Series single oven. You
must allow for a 2
1
/
2
" (64) space between
the oven rough openings. Also, a separate
inner wall is required for each oven between
openings.
IMPORTANT NOTE: Unless you are using
cabinets deeper than 24" (610) for a standard
installation or 25" (635) for a flush inset instal-
lation, it is recommended that the electrical
supply be placed in an adjacent cabinet within
reach of the conduit. Choose the location
shown in the illustration that best suits your
installation.
E S E R I E S B U I L T - I N O V E N S
27
3
/
16
"
(691)
OPENING
HEIGHT
28
1
/
2
"
min
(724)
FLUSH
INSET
HEIGHT
30
3
/
8
"
min (772)
FLUSH INSET WIDTH
28
1
/
2
"
(724)
OPENING WIDTH
5"
(127)
4"
(102)
E
E
E
E
36"
(914)
RECOMMENDED CABINET WIDTH
33"
min (838)
24"
min
(610)
OPENING
DEPTH
1"
(25)
25"
min
(635)
FLUSH
INSET
DEPTH
7
/
16
"
(11)
7
/
8
"
(22)
ELECTRICAL LOCATION
WITHIN OPENING
APPLIES ONLY TO
CABINETS DEEPER
THAN 25" (635)
SIDE VIEW
TOP VIEW
I N S T A L L A T I O N S P E C I F I C A T I O N S
E Series Built-In Single Oven
Flush Inset Installation—Wall Application
For flush inset installations, cabinet materials
must be able to withstand temperatures up
to 195˚F (90˚C) to avoid damage from high