TDK 2U GENESYS 5KW User Manual
Page 40
83-515-000 Rev. B
32
4.4.1
SW1 position function
Refer to Table 4-3 for description of SW1 position functions. The factory default setting is Down
for all positions.
Table 4-3: SW1 Positions Functions
Position
Function
DOWN (Factory default)
UP
SW1-1
Output Voltage
Remote Analog Programming
Output Voltage
Programmed by
Front Panel
Output Voltage
Programmed by remote analog
External Voltage or External Resistor
SW1-2
Output Current
Remote Analog programming
Output Current
Programmed by
Front Panel
Output Current
programmed by remote analog
External Voltage or External Resistor
SW1-3
Programming Range Select
(Remote voltage/resistive)
0-5V/(0-5Kohm)
0-10V/(0-10Kohm)
SW1-4
Output Voltage and
Current Monitoring Range
0-5V
0-10V
SW1-5
Shut-Off Logic select
On: High (2-15V) or Open
Off: Low (0-0.6V) or Short
On: High (0-0.6V) or Short
Off: Low (2-15V) or Open
SW1-6
RS232/485 select
RS232 interface
RS485 interface
SW1-7
Output Voltage
Resistive Programming
Output Voltage
programmed by
Front Panel
Output Voltage
programmed by
External resistor
SW1-8
Output Current
Resistive Programming
Output Current Limit
Programmed by
Front Panel
Output Current Limit
Programmed by
External Resistor
SW1-9
Enable/Disable control
Rear panel
Enable/Disable control is
not Active
Rear panel
Enable/Disable control
is Active
4.4.2
Resetting the SW1 switch
Before making any changes to the SW1 switch setting, disable the power supply output by press-
ing the front panel OUT button. Ensure that the Output Voltage falls to zero and the OUT LED is
off. Then use any small flat-bladed screwdriver to change the SW1 switch setting.