TDK 2U GENESYS 5KW User Manual
Page 39
83-515-000 Rev. B
31
Table 4-2: Rear panel Connections and Controls (continued)
Number
Item
Description
Section
4
Remote Out
connector
RJ-45 type connector, used for daisy-chaining power supplies to
form a serial communication bus.
7.3
7.4
5
J1 Analog pro-
gramming and
monitoring con-
nector
Connector for remote analog interface. Includes Output Voltage
and Current programming and monitoring signals, Shut-off control
(electrical signal), Enable/Disable control (dry-contact), Power
Supply OK (PS_OK) signal and operation mode (CV/CC) signal.
4.5
6
SW1 Setup
switch
Nine position DIP-switch for selecting remote programming and
monitoring modes for Output Voltage, Output Current and other
control functions.
4.4
4.4.1
4.4.2
7
J2 Remote
sense connector
Connector for making remote sensing connections to the load for
regulation of the load voltage and compensation of load wire
drop.
3.8.2
3.10.2
3.10.3
8
Blank Sub-plate
Blank sub-plate for standard units. Isolated Remote Analog pro-
gramming connector for units equipped with Isolated Analog con-
trol option. IEEE connector for units equipped with IEEE pro-
gramming option (shown).
9
IEEE switch
Two position DIP-switch for selecting IEEE mode or
RS232/RS485 mode when IEEE option is installed.
10
Ground
stud
M4 stud and hardware for chassis ground connection.
4.4 REAR PANEL SW1 SETUP SWITCH
The SW1 Setup switch (see Fig.4-3) is a 9-position DIP-switch that allows the user to choose the fol-
lowing:
Internal or remote programming for Output Voltage and Output Current.
Remote voltage or resistive programming of Output Voltage and Output Current.
Select range of remote voltage and resistive programming.
Select range of output Voltage and Output Current monitoring.
Select the Remote Shut-Off control logic.
Select between RS232 and RS485 communication interface.
Enable or disable the rear panel Enable/Disable control (dry contact).
Fig.4-3: SW1 setup DIP-switch
1
2
3
4
5
6
7
8
9