Chapter 3 installation – TDK 2U GENESYS 5KW User Manual
Page 21
83-515-000 Rev. B
13
NOTE
Genesys
TM
power supplies generate magnetic fields, which might affect
the operation of other instruments. If your equipment is susceptible to
magnetic fields, do not position it adjacent to the power supply.
WARNING
To avoid electric shock hazard, do not insert conductive parts
through the front panel slits.
CHAPTER 3
INSTALLATION
3.1 GENERAL
This Chapter contains instructions for initial inspection, preparation for use and repackaging for ship-
ment. Connection to PC, setting the communication port and linking Genesys
TM
power supplies are
described in Chapter 7.
3.2 PREPARATION FOR USE
In order to be operational the power supply must be connected to an appropriate AC source. The AC
source voltage should be within the power supply specification. Do not apply power before reading
Section 3.3, 3.6 and 3.7.
Table 3-1 below, describes the basic setup procedure. Follow the instructions in Table 3-1 in the se-
quence given to prepare the power supply for use.
Step no.
Item
Description
Reference
1
Inspection
Initial physical inspection of the power supply
Section 3.3
2
Installation
Installing the power supply,
Ensuring adequate ventilation.
Section 3.4
Section 3.5
3
AC source
AC source requirements
Connecting the power supply to the AC source
Section 3.6
Section 3.7
4
Test
Turn-on checkout procedure.
Section 3.8
5
Load connection
Wire size selection. Local/Remote sensing. Single
or multiple loads.
Section 3.9
6
Default setting
The power supply setting at shipment.
Section 7.2.1
Table 3-1: Basic setup procedure
3.3 INITIAL INSPECTIONS
Prior to shipment this power supply was inspected and found free of mechanical or electrical defects.
Upon unpacking of the power supply, inspect for any damage, which may have occurred in transit.
The inspection should confirm that there is no exterior damage to the power supply such as broken
knobs or connectors and that the front panel and meters face are not scratched or cracked. Keep all
packing material until the inspection has been completed. If damage is detected, file a claim with car-
rier immediately and notify the TDK-Lambda Americas Inc. sales or authorized service facility nearest
you.
WARNING
The Genesys
TM
series is intended only for installation in Restricted
Access Location (RAL). Access to Hazardous parts (rear side of
the power supply) shall be prevented after installation.